Zobrazeno 1 - 10
of 132
pro vyhledávání: '"Inhwa Jung"'
Publikováno v:
IEEE Access, Vol 10, Pp 22712-22723 (2022)
Recent real-time systems have been gradually connected externally through the Internet. As each subsystem constituting a system has been developed from different vendors, the number of cases of security vulnerabilities in communication between subsys
Externí odkaz:
https://doaj.org/article/96fe467259f146d29becfd89d091889f
Autor:
Jaehyuk Lee, Jeongpyo Hong, Jungwon Lee, Changgyu Lee, Tony Kim, Young Jeong, Kwanghee Kim, Inhwa Jung
Publikováno v:
Membranes, Vol 13, Iss 8, p 707 (2023)
A cell filtration platform that affords accurate size separation and minimizes fouling was developed. The platform features an ultra-thin porous membrane (UTM) filter, a pumping head filtration with backflush (PHF), and cell size measurement (CSM) so
Externí odkaz:
https://doaj.org/article/bcbd2c3908a94d3e90ab472c97ec8233
Publikováno v:
Veins and Lymphatics, Vol 7, Iss 1 (2018)
An optimal protocol is needed to validate the performance of future interface pressure sensors for compression garments when using a sphygmomanometer. PicoPress® was used on a rigid plastic cylinder (r=4 cm). An FDA-cleared aneroid sphygmomanometer
Externí odkaz:
https://doaj.org/article/a761b29455e340868f73d46be8744b04
Publikováno v:
The Journal of Korean Institute of Information Technology. 19:1-9
Autor:
Inhwa Jung, Jae Hyung Kim
Publikováno v:
The Journal of Korean Institute of Communications and Information Sciences. 46:361-369
Autor:
Masahiro Irie, Kelia A. Human, Christopher Ogle, Kun Hyuck Lee, Hany Arafa, Alina Y. Rwei, Jingyue Cao, Jungwoo Kim, Han Heul Jo, Blake V. Parsons, Sung Hoon Lee, Ha Uk Chung, Dominic Grande, Jun Bin Park, Jong Yoon Lee, Emily Suen, Debra E. Weese-Mayer, Yeojeong Yun, Yerim Park, Casey M. Rand, Yonggang Huang, Jean Won Kwak, Emma C. Dunne, Ian C. Odland, Hokyung Jang, William Reuther, John A. Rogers, Myeong Namkoong, Manish Patel, Aaron Hamvas, Max A. Paulus, Sarah Rigali, Zhaoqian Xie, Molly Schau, Dong Hyun Kim, Dennis Ryu, Avani Shukla, Yeshou Xu, John D. Leedle, Seung Sik Kim, Brad Hopkins, Taeyoung Son, Raudel Avila, Amy S. Paller, Lauren E. Marsillio, Zena Leah Harris, Aurélie Hourlier-Fargette, Inhwa Jung, Anthony Banks, Jongwon Kim, Allison Bradley, Robin J. Kim, Elena Kulikova, Claire Liu, Andrea S. Carlini, Shuai Xu, Kelsey B. Fields, Joo Hee Lee, Hyoungjo Hahm, Vinaya R. Soundararajan, Hyun Soo Kim, Ayelet Ollech
Publikováno v:
Nature Medicine. 26:418-429
Standard clinical care in neonatal and pediatric intensive-care units (NICUs and PICUs, respectively) involves continuous monitoring of vital signs with hard-wired devices that adhere to the skin and, in certain instances, can involve catheter-based
Publikováno v:
Applied Acoustics. 203:109194
Autor:
Jaehyuk Lee, Inhwa Jung
Publikováno v:
Applied Acoustics. 151:10-21
In this paper, the effect of graphene oxide (GO) loading on sound-absorbing properties of open cell polyurethane foam (PU) was investigated. GO was impregnated into PU foam by a step-by-step vacuum-assisted process. It was found that sound-absorbing
Autor:
Jean Won Kwak, Ted S. Chung, Hyoyoung Jeong, Keum San Chun, Inhwa Jung, Sang Min Won, Shuai Xu, Kyeongha Kwon, Yoonseok Park, David Pontes, Brianna R. Kampmeier, Hokyung Jang, John A. Rogers, Sung Soo Kwak, Youn J. Kang, Jong Uk Kim, Michael Zhang, Hanjun Ryu, Seon Hee Seo, Jeffrey Zhao, Haiwen Luan, Da Som Yang, Yonggang Huang
Publikováno v:
Science Advances
Soft, wireless sensors monitor the temperature and interface pressure of the patient’s skin for compression therapy.
Therapeutic compression garments (TCGs) are key tools for the management of a wide range of vascular lower extremity condition
Therapeutic compression garments (TCGs) are key tools for the management of a wide range of vascular lower extremity condition
Autor:
Yoonseok Park, Yonggang Huang, Jean Won Kwak, Xuexian Chen, Jessica Yohay, Jongwon Kim, Anthony Banks, Dominic Grande, John A. Rogers, Donghyun Kim, Raudel Avila, Ryan Caldwell, Jong Yoon Lee, Surabhi R. Madhvapathy, Zhaoqian Xie, Inhwa Jung, Dennis Ryu, Claire Liu, Da Som Yang, Christopher Ogle, Cunman Liang, Kyeongha Kwon, Mengdi Han, Stefania Fatone, Myeong Namkoong, Manish J. Patel, Xu Guo, Shuai Xu, Ha Uk Chung
Publikováno v:
Sci Transl Med
Precise form-fitting of prosthetic sockets is important for the comfort and well-being of persons with limb amputations. Capabilities for continuous monitoring of pressure and temperature at the skin-prosthesis interface can be valuable in the fittin