Zobrazeno 1 - 10
of 125
pro vyhledávání: '"Image guided radiosurgery"'
Publikováno v:
Zhongguo yiliao qixie zazhi, Vol 48, Iss 4, Pp 434-439 (2024)
This paper describes the design of an innovative linear accelerator image-guided radiosurgery (IGRS) device, which is based on a composite twofold rotary gantry structure. The paper discusses five aspects of the innovative device: its overall composi
Externí odkaz:
https://doaj.org/article/30877f0c3ccd4997b6f60db75cb2227a
Publikováno v:
Clinical and Translational Radiation Oncology, Vol 48, Iss , Pp 100821- (2024)
Background and purpose: Radiosurgery has been extensively studied for its efficacy and safety in the management of trigeminal neuralgia (TN). However, among the plethora of relevant studies in the literature, only a restricted number have been conduc
Externí odkaz:
https://doaj.org/article/4fa6ec6b687f4ca7a8bdf3abc4324ad5
Publikováno v:
World Neurosurgery: X, Vol 22, Iss , Pp 100325- (2024)
Background: Stereotactic radiosurgery (SRS) has recently gained space as an accepted non-invasive alternative treatment option for drug resistant Glossopharyngeal neuralgia (GPN). The purpose of this systematic review was to provide an overview of th
Externí odkaz:
https://doaj.org/article/42943f4cf35b4c8ea53e6bb2a833badf
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
Cureus
Image-guidance for frame-based stereotaxis is facilitated by incorporating three to four N-localizers or Sturm-Pastyr localizers into a stereotactic frame. An extant frame that incorporates only two N-localizers violates the fundamental principle of
Autor:
Lydia Koi, Tobias Hölscher, Michael Baumann, Frank Paulsen, Jörg Kotzerke, Manfred P. Wirth, Steffen Löck, Arndt-Christian Müller, Fabian Lohaus, Daniel Zips, Mechthild Krause, Christian Thomas, Klaus Zöphel
Publikováno v:
European Urology Oncology 5(2022)1, 44-51
Background: Local ablative radiotherapy (aRT) of oligometastatic prostate cancer (PCa) is very promising and has become a focus of current clinical research. Objective: We hypothesize that aRT is safe and effective in gallium-68 prostate-specific mem
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::72bebdd5b945f87b165c7eb9daf7710c
https://www.hzdr.de/publications/Publ-33965-1
https://www.hzdr.de/publications/Publ-33965-1
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
Cureus
Image guidance for frame-based stereotaxis is facilitated by incorporating three to four Sturm-Pastyr (SP) localizers into a stereotactic frame. Typically, each SP localizer enables the calculation of one set of \begin{document}\left ( x,y,z \right )
Publikováno v:
Cureus
The N-localizer and the Sturm-Pastyr localizer are two technologies that facilitate image-guided stereotactic surgery. Both localizers enable the geometric transformation of tomographic image data from the two-dimensional coordinate system of a medic