Zobrazeno 1 - 10
of 11
pro vyhledávání: '"Ilona Šperlingová"'
The results of HbA1c measurement and its comparison with reference method values in an EQA programme
Publikováno v:
Accreditation and Quality Assurance. 15:239-243
This article describes the effect of a change in reference method for HbA1c measurement on results in our EQA programme. Important indicators of analytical quality, particularly reproducibility, bias and uncertainty, were assessed. Basic analytical q
Publikováno v:
Accreditation and Quality Assurance. 12:146-150
In this paper, the creation of a certified reference material for urinary creatinine is described. We used the Jaffe method and HPLC method for establishment of the certified value. Homogeneity tests are also described. We obtained material with suff
Publikováno v:
Sperlingová, I; Dabrowská, L; Stránský, V; Kucera, J; Tichý, M (2006). Human urine certified reference material CZ 6010: creatinine and toluene metabolites (hippuric acid and o-cresol) and a benzene metabolite (phenol). Analytical and bioanalytical chemistry, 387(7), pp. 2419-2424. Heidelberg: Springer 10.1007/s00216-006-0708-7
A reference material for the biological monitoring of occupational exposure to toluene, benzene and phenol was prepared. O-cresol and hippuric acid (metabolites of toluene) are used for the biological monitoring of occupational exposure to toluene. P
Publikováno v:
Accreditation and Quality Assurance. 11:231-235
The candidate reference material (RM) was prepared by freeze-drying pooled urine samples obtained from healthy persons occupationally exposed to toluene. Homogeneity testing yielded no significant differences of urinary concentrations of o-cresol and
Publikováno v:
Analytical and Bioanalytical Chemistry. 378:536-543
A rapid HPLC method for the determination of carboxylic acids in urine samples using a Chromolith Performance RP/18e 100/4.6 with Chromolith Guard Cartridge RP/18e 10/4.6 (Merck KgaA, Darmstadt, Germany) was developed. The method facilitates the simu
Publikováno v:
Accreditation and Quality Assurance. 8:113-116
A preliminary batch of the reference material was prepared by freeze-drying pooled urine samples obtained from healthy persons occupationally exposed to styrene. Tests for homogeneity and stability were performed by determining urine concentrations o
Publikováno v:
Fresenius' Journal of Analytical Chemistry. 361:756-760
Two batches of a reference material (RM) “total protein in human urine” were prepared for quality assurance in the determination of human urinary proteins. The material was prepared by freeze-drying of a pooled urine sample obtained from healthy
Autor:
Ludmila Dabrowská, Ilona Šperlingová, Šárka Dušková, Milon Tichy, Jan Kučera, Vladimír Stránský, Monika Tvrdíková
Publikováno v:
Analytical and bioanalytical chemistry. 397(2)
Ethylene glycol monobutyl ether (EGBE), an industrial solvent, is absorbed by the body not only by inhalation but also by dermal absorption (liquid or vapour). EGBE is metabolized to butoxyacetic acid (BAA). Pooled freeze-dried urine candidate refere
Publikováno v:
Analytical and bioanalytical chemistry. 378(5)
The reference material was prepared by freeze-drying pooled urine samples obtained from healthy persons occupationally exposed to styrene. The concentrations of mandelic acid (MA), phenylglyoxylic acid (PGA), and hippuric acid (HA) in urine were dete
Publikováno v:
Traceability in Chemical Measurement ISBN: 9783540439899
Some problems arising in the establishment of the traceabili- ty of the certified reference materi- al (CRM) CZ 6007a (total protein, creatinine and stress indicators) are discussed. Bovine serum albumin is recommended as a calibration standard for t
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::413d37c26b3a0492f9481dc66d619349
https://doi.org/10.1007/3-540-27093-0_36
https://doi.org/10.1007/3-540-27093-0_36