Zobrazeno 1 - 10
of 750
pro vyhledávání: '"Iguaz A"'
Autor:
Ahyoune, S., Altenmueller, K., Antolin, I., Basso, S., Brun, P., Candon, F. R., Castel, J. F., Cebrian, S., Chouhan, D., Della Ceca, R., Cervera-Cortes, M., Chernov, V., Civitani, M. M., Cogollos, C., Costa, E., Cotroneo, V., Dafni, T., Derbin, A., Desch, K., Diaz-Martin, M. C., Diaz-Morcillo, A., Diez-Ibanez, D., Pardos, C. Diez, Dinter, M., Doebrich, B., Drachnev, I., Dudarev, A., Ezquerro, A., Fabiani, S., Ferrer-Ribas, E., Finelli, F., Fleck, I., Galan, J., Galanti, G., Galaverni, M., Garcia, J. A., Garcia-Barcelo, J. M., Gastaldo, L., Giannotti, M., Giganon, A., Goblin, C., Goyal, N., Gu, Y., Hagge, L., Helary, L., Hengstler, D., Heuchel, D., Hoof, S., Iglesias-Marzoa, R., Iguaz, F. J., Iniguez, C., Irastorza, I. G., Jakovcic, K., Kaefer, D., Kaminski, J., Karstensen, S., Law, M., Lindner, A., Loidl, M., Loiseau, C., Lopez-Alegre, G., Lozano-Guerrero, A., Lubsandorzhiev, B., Luzon, G., Manthos, I., Margalejo, C., Marin-Franch, A., Marques, J., Marutzky, F., Menneglier, C., Mentink, M., Mertens, S., Miralda-Escude, J., Mirallas, H., Muleri, F., Muratova, V., Navarro-Madrid, J. R., Navick, X. F., Nikolopoulos, K., Notari, A., Nozik, A., Obis, L., Ortiz-de-Solorzano, A., O'Shea, T., von Oy, J., Pareschi, G., Papaevangelou, T., Perez, K., Perez, O., Picatoste, E., Pivovaroff, M. J., Porron, J., Puyuelo, M. J., Quintana, A., Redondo, J., Reuther, D., Ringwald, A., Rodrigues, M., Rubini, A., Rueda-Teruel, S., Rueda-Teruel, F., Ruiz-Choliz, E., Ruz, J., Schaffran, J., Schiffer, T., Schmidt, S., Schneekloth, U., Schoenfeld, L., Schott, M., Segui, L., Singh, U. R., Soffitta, P., Spiga, D., Stern, M., Straniero, O., Tavecchio, F., Unzhakov, E., Ushakov, N. A., Vecchi, G., Vogel, J. K., Voronin, D. M., Ward, R., Weltman, A., Wiesinger, C., Wolf, R., Yanes-Diaz, A., Yu, Y.
BabyIAXO is the intermediate stage of the International Axion Observatory (IAXO) to be hosted at DESY. Its primary goal is the detection of solar axions following the axion helioscope technique. Axions are converted into photons in a large magnet tha
Externí odkaz:
http://arxiv.org/abs/2411.13915
Autor:
Kallitsopoulou, A., Aleksan, R., Angelis, Y., Aune, S., Bortfeldt, J., Brunbauer, F., Brunoldi, M., Chatzianagnostou, E., Datta, J., Desforge, D., Fanourakis, G., Fiorina, D., Floethner, K. J., Gallinaro, M., Garcia, F., Giomataris, I., Gnanvo, K., Iguaz, F. J., Janssens, D., Kovacic, M., Kross, B., Legou, P., Lisowska, M., Liu, J., Lupberger, M., Maniatis, I., McKisson, J., Meng, Y., Muller, H., Oliveri, E., Orlandini, G., Pandey, A., Papaevangelou, T., Pomorski, M., Ropelewski, L., Sampsonidis, D., Scharenberg, L., Schneider, T., Scorsone, E., Sohl, L., van Stenis, M., Tsipolitis, Y., Tzamarias, S. E., Utrobicic, A., Vai, I., Veenhof, R., Vitulo, P., Wang, X., White, S., Xi, W., Zhang, Z., Zhou, Y.
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment,1069,169920,2024
The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov light emit
Externí odkaz:
http://arxiv.org/abs/2411.02532
The detector group of Synchrotron SOLEIL is monitoring the performance of Energy-Resolved Detectors (EDX) and their associated electronics since last five years. A characterization procedure has been developed for this purpose and for Site Acceptance
Externí odkaz:
http://arxiv.org/abs/2409.05515
Autor:
Cools, A., Ferrer-Ribas, E., Papaevangelou, T., Pollacco, E. C., Lisowska, M., Brunbauer, F. M., Oliveri, E., Iguaz, F. J.
Optically read out gaseous detectors are used in track reconstruction and imaging applications requiring high granularity images. Among resolution-determining factors, the amplification stage plays a crucial role and optimisations of detector geometr
Externí odkaz:
http://arxiv.org/abs/2407.15491
Autor:
Lisowska, M., Aleksan, R., Angelis, Y., Aune, S., Bortfeldt, J., Brunbauer, F., Brunoldi, M., Chatzianagnostou, E., Datta, J., Dehmelt, K., Fanourakis, G., Ferry, S., Fiorina, D., Floethner, K. J., Gallinaro, M., Garcia, F., Giomataris, I., Gnanvo, K., Iguaz, F. J., Janssens, D., Kallitsopoulou, A., Kovacic, M., Kross, B., Lai, C. C., Legou, P., Liu, J., Lupberger, M., Maniatis, I., McKisson, J., Meng, Y., Muller, H., De Oliveira, R., Oliveri, E., Orlandini, G., Pandey, A., Papaevangelou, T., Pomorski, M., Robert, M., Ropelewski, L., Sampsonidis, D., Scharenberg, L., Schneider, T., Scorsone, E., Sohl, L., van Stenis, M., Tsipolitis, Y., Tzamarias, S., Utrobicic, A., Vai, I., Veenhof, R., Viezzi, L., Vitulo, P., Volpato, C., Wang, X., White, S., Xi, W., Zhang, Z., Zhou, Y.
The PICOSEC Micromegas detector is a~precise-timing gaseous detector based on a~Cherenkov radiator coupled with a~semi-transparent photocathode and a~Micromegas amplifying structure, targeting a~time resolution of tens of picoseconds for minimum ioni
Externí odkaz:
http://arxiv.org/abs/2407.09953
We revisit the question of how generic is the formation of primordial black holes via self-resonant growth of inflaton fluctuations in the post-inflationary, preheating phase. Using analytical and lattice calculations, we find that primordial black h
Externí odkaz:
http://arxiv.org/abs/2406.09122
Autor:
Wang, X., Aleksan, R., Angelis, Y., Bortfeldt, J., Brunbauer, F., Brunoldi, M., Chatzianagnostou, E., Datta, J., Degmelt, K., Fanourakis, G., Fiorina, D., Floethner, K. J., Gallinaro, M., Garcia, F., Giomataris, I., Gnanvo, K., Iguaz, F. J., Janssens, D., Kallitsopoulou, A., Kovacic, M., Kross, B., Legou, P., Lisowska, M., Liu, J., Maniatis, I., McKisson, J., Meng, Y., Muller, H., Oliveri, E., Orlandini, G., Pandey, A., Papaevangelou, T., Pomorski, M., Ropelewski, L., Sampsonidis, D., Scharenberg, L., Schneider, T., Shang, L., Shao, M., Sohl, L., van Stenis, M., Tsipolitis, Y., Tzamarias, S. E., Utrobicic, A., Vai, I., Veenhof, R., Vitulo, P., White, S., Xi, W., Zhang, Z., Zhou, Y.
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising tim
Externí odkaz:
http://arxiv.org/abs/2406.08712
Autor:
Utrobicic, A., Aleksan, R., Angelis, Y., Bortfeldt, J., Brunbauer, F., Brunoldi, M., Chatzianagnostou, E., Datta, J., Dehmelt, K., Fanourakis, G., Fiorina, D., Floethner, K. J., Gallinaro, M., Garcia, F., Giomataris, I., Gnanvo, K., Iguaz, F. J., Janssens, D., Kallitsopoulou, A., Kovacic, M., Kross, B., Legou, P., Lisowska, M., Liu, J., Lupberger, M., Maniatis, I., McKisson, J., Meng, Y., Muller, H., Oliveri, E., Orlandini, G., Pandey, A., Papaevangelou, T., Pomorski, M., Ropelewski, L., Sampsonidis, D., Scharenberg, L., Schneider, T., Sohl, L., van Stenis, M., Tsipolitis, Y., Tzamarias, S. E., Vai, I., Veenhof, R., Vitulo, P., Wang, X., White, S., Xi, W., Zhang, Z., Zhou, Y.
This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical c
Externí odkaz:
http://arxiv.org/abs/2406.05657
Synchrotron radiation facilities provide highly polarized X-ray beams across a wide energy range. However, the exact type and degree of polarization varies according to the beamline and experimental setup. To accurately determine the angle and degree
Externí odkaz:
http://arxiv.org/abs/2309.05587
Autor:
Utrobicic, Antonija, Angelis, Yannis, Aune, Stephan, Bortfeldt, Jonathan, Brunbauer, Florian, Chatzianagnostou, Evridiki, Dehmelt, Klaus, Desforge, Daniel, Fanourakis, George, Floethner, Karl Jonathan, Gallinaro, Michele, Garcia, Francisco, Garg, Prakhar, Giomataris, Ioannis, Gnanvo, Kondo, Gustavsson, Thomas, Iguaz, Francisco Jose, Janssens, Djunes, Kallitsopoulou, Alexandra, Kovacic, Marinko, Legou, Philippe, Lisowska, Marta, Liu, Jianbei, Lupberger, Michael, Malace, Simona, Maniatis, Ioannis, Meng, Yue, Muller, Hans, Oliveri, Eraldo, Orlandini, Giorgio, Papaevangelou, Thomas, Pomorski, Michal, Ropelewski, Leszek, Sampsonidis, Dimos, Scharenberg, Lucian, Schneider, Thomas, Sohl, Lukas, van Stenis, Miranda, Tsipolitis, Yorgos, Tzamarias, Spyros, Veenhof, Rob, Wang, Xu, White, Sebastian, Zhang, Zhiyong, Zhou, Yi
The PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a semi-transparent photocathode and a Micromegas amplification structure. The first proof of concept single-channel small area prototype was able to achieve ti
Externí odkaz:
http://arxiv.org/abs/2304.00056