Ιn a 76-year old man with a dual-chamber ICD implanted five years ago, dizzy spells and significant bradycardia on Holter were not initially recognized as inhibition of bradycardia pacing, due to oversensing. Hospital admission was deemed necessary
Externí odkaz:
https://doaj.org/article/1b3b9afebd3f40c4b73af08ac0c283e4
Autor:
Jian-Ming Li, MD, PhD, FHRS, Yanhui Li, MD, PhD, Venkatakrishna Tholakanahalli, MD, FHRS, David G. Benditt, MD, FHRS
Publikováno v:
HeartRhythm Case Reports, Vol 6, Iss 3, Pp 148-152 (2020)
Externí odkaz:
https://doaj.org/article/411b5576437047e9b8fa3243fb0ffd67
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
Trends in Cardiovascular Medicine. 32:84-89
Cardiac implantable electronic devices establish proper therapy for the prevention of sudden cardiac death, significantly reducing the morbidity and mortality of patients with arrhythmias and heart failure. It is well-known that the number of electro
Autor:
Monica Cozzolino, Maria Castellano, Domenico Gianfrancesco, Raffaele Pulli, Domenico Carretta, Lucrezia De Michele, Paolo Colonna, Domenico Angiletta, Pasquale Pedote, Carlo D'Agostino
Publikováno v:
J Cardiol Cases
Inadvertent placement of pacemaker and implantable cardioverter-defibrillator (ICD) leads in the left ventricle is a rare but well-recognized complication of device implantation. We report a case of an unicameral ICD lead inadvertently placed through
Publikováno v:
Indian Pacing and Electrophysiology Journal
Indian Pacing and Electrophysiology Journal, Vol 21, Iss 3, Pp 182-185 (2021)
Indian Pacing and Electrophysiology Journal, Vol 21, Iss 3, Pp 182-185 (2021)
Ιn a 76-year old man with a dual-chamber ICD implanted five years ago, dizzy spells and significant bradycardia on Holter were not initially recognized as inhibition of bradycardia pacing, due to oversensing. Hospital admission was deemed necessary
Publikováno v:
JACC Case Reports
A 53-year-old man with a subcutaneous implantable cardioverter-defibrillator (S-ICD) presented with inappropriate shocks. He underwent device extraction, and the lead was freed using a rotating mechanical dilator sheath. As patients with S-ICDs get o
Autor:
Demetrio Pittarello, Lorenzo Bagozzi, Assunta Fabozzo, Vincenzo Tarzia, Fabio Zanella, Federico Migliore, Chiara Tessari, Gino Gerosa, Emanuele Bertaglia
Publikováno v:
Journal of Cardiovascular Electrophysiology. 32:1778-1781
AngioVac system (AngioDynamics) has already proved to be a useful tool in the treatment of thrombotic and endocarditic formations concerning the venous district. Herein, the AngioVac aspiration system combined with the bidirectional rotational Evolut
Autor:
Oswaldo Valencia, Lisa W M Leung, Manav Sohal, Andrew T Cox, Ian Beeton, Mark M Gallagher, Zia Zuberi, Nilanka Mannakkara, Idris Harding, Zaki Akhtar, Fadi Jouhra, Simon Pearse, Anthony Li, Zhong Chen, Ahmed I Elbatran, Abhay Bajpai, Hanney Gonna
Publikováno v:
Journal of Cardiovascular Electrophysiology. 32:1131-1139
Background Cardiac resynchronization therapy-defibrillator (CRT-D) implantation via the cephalic vein is feasible and safe. Recent evidence has suggested a higher implantable cardioverter-defibrillator (ICD) lead failure in multi-lead defibrillator t