Zobrazeno 1 - 10
of 96
pro vyhledávání: '"I. I. Borisov"'
Publikováno v:
Thermophysics and Thermal Power Engineering. 42:61-67
Numerical research of high-temperature corrosion of steel blades of the swirler of a pulverized coal burner of the TPP-312 boiler in real conditions of its operation is carried out. Data on the dynamics of oxidation of the blade surface for two steel
Publikováno v:
International Journal of Heat and Mass Transfer. 175:121404
Swirling flow heat transfer and hydrodynamics were studied experimentally in the round passage, simulating the blade cyclone cooling. The smooth passage with one- and two inclined-tangential flow supply and the additional co-swirling flow at the inle
Publikováno v:
Gornyi Zhurnal. :102-106
Publikováno v:
Journal of Engineering Physics and Thermophysics. 90:637-643
The results of numerical simulation and experimental investigation of the efficiency of film cooling behind a row of holes in a trench in the range of blowing ratio variation 0.5 ≤ m ≤ 2.0 are presented. This scheme is of practical interest for u
Publikováno v:
International Journal of Heat and Mass Transfer. 159:120055
The available database has shown film holes embedded into trench and surface craters demonstrate significant improvements in the film cooling performance over conventional inclined round holes. In this paper two new designs of a single array of round
Publikováno v:
Mining Industry Journal (Gornay Promishlennost). 147:85-86
Publikováno v:
NTU "KhPI" Bulletin: Power and heat engineering processes and equipment. :56-62
Autor:
V. E. Borisov, V. E. Khitrikheev, I. A. Stepanov, B. Z. Tsybikov, E. V. Artyukhova, I. I. Borisova
Publikováno v:
Инновационная медицина Кубани, Vol 0, Iss 1, Pp 103-110 (2023)
Background: Caused by the degenerative spine disease (DSD), the pain syndrome in the lumbosacral spine and lower extremities represents a socioeconomic problem. Nowadays, minimally invasive methods of treatment, in particular, epidural injections (EI
Externí odkaz:
https://doaj.org/article/a364ccd5de384802b4ed94db32557b7c
Publikováno v:
Thermophysics and Aeromechanics. 21:545-552
Results of an experimental study of flat-plate film cooling effectiveness achieved with an inlet double jet scheme are reported. At low (m = 0.5) and medium (m = 1.0) blowing ratio the average film cooling effectiveness is about 20 % greater of the t
Publikováno v:
Thermophysics and Aeromechanics. 20:713-719
Results of an experimental study of a flat plate film cooling efficiency from a single row of inclined holes embedded in a “shallow” trench are presented. It is shown the cooling efficiency of such a configuration is much greater than that of the