Zobrazeno 1 - 10
of 24
pro vyhledávání: '"I. Gusdal"'
Autor:
S. Oh, J.S.C. McKee, R. Pogson, A. McIlwain, V. Derenchuk, I. Gusdal, J. Lancaster, J. Bruckshaw
Publikováno v:
Computing in Accelerator Design and Operation ISBN: 9783540139096
The magnetic field of the University of Manitoba compact cyclotron has been measured in high vacuum by polar scanning with 52 flip coils. This was a unique invacuo operation was required because the Curie effect on invar material is used to trim the
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::15f6c49e5812a6e26b83ea512fda7849
https://doi.org/10.1007/3540139095_139
https://doi.org/10.1007/3540139095_139
Publikováno v:
Journal of Radioanalytical Chemistry. 65:57-60
An experience at123I production with a low beam current cyclotron used in combination with the124Te(p, 2n)123I reaction on 90.8% enrichment124Te is described.
Publikováno v:
IEEE Transactions on Nuclear Science. 30:2089-2091
A variable energy cyclotron with six separated sectors is proposed for the acceleration of polarized and unpolarized light positive and negative charge state ions. The energy range within which these ions are accelerated and extracted is given. The r
Autor:
J. Lancaster, J. Bruckshaw, J.S.C. McKee, S. Oh, F. Konopasek, M. Yoon, C. A. Smith, H.W. Uzat, V. Derenchuk, I. Gusdal, J. R. Anderson
Publikováno v:
IEEE Transactions on Nuclear Science. 32:2724-2726
The University of Manitoba Cyclotron has completed an extensive major upgrading that has resulted in a virtually new and different facility. The latest modification has involved reshaping the magnetic field through the use of iron shims, the design a
Autor:
A. McIlwain, J. Lancaster, R. Pogson, J. Bruckshaw, I. Gusdal, S. Oh, J.S.C. McKee, V. Derenchuk
Publikováno v:
Nuclear Instruments and Methods in Physics Research. 207:493-495
A magnetic field mapping system having 52 flipping coils has been developed at the University of Manitoba. Measurements were made in vacuo with an estimated relative error of ±0.04%.
Publikováno v:
IEEE Transactions on Nuclear Science. 32:2954-2956
One of the major aspects of the present University of Manitoba upgrading project was the construction and implementation of a new RF accelerating system. The new system includes two dees, each tuned with a separate rectangular coaxial tuning stub. Th
Publikováno v:
Nuclear Instruments and Methods. 136:15-17
Axial injection of H − ions into the University of Manitoba spiral ridge cyclotron has resulted in the production of 5 μA of extracted proton beam at 30 MeV, with a total transmission efficiency in excess of 10%. H + beams of energy up to and incl
Publikováno v:
AIP Conference Proceedings.
Complete depolarisation of polarised H− ions accelerated in the University of Manitoba Cyclotron has been observed. The origin of the resonance will be examined and several consequences for the use of polarised atomic ions will be outlined.
Publikováno v:
Cancer detection and prevention. 8(1-2)
Positron-emitting 132Cs (t1/2 = 6.47 days) was generated from stable 133CsCl via the 133Cs (p,pn) 132Cs reaction. BALB/c mice, bearing implanted MT296 mammary tumors, were given 4.6 mEq kg-1 of 132CsCl via a single intraperitoneal injection. Postinje
Publikováno v:
AIP Conference Proceedings.
A Lamb‐shift source for polarised beams of D− and H0 ions for the University of Manitoba Cyclotron is now in operation. The polarised source is of the nuclear spin filter type. A velocity filter is used in the source for the removal of the direct