I Longair, Jemma L Walker, F M Mattes, Richard S. Tedder, Thomas A. Fox, Mallika Sekhar, Eric Houston, Michael Ankcorn, Deepak Suri, Claire Nicholas, Samreen Ijaz
Publikováno v:
British journal of haematology. 186(1)
Publikováno v:
Journal of Clinical Pathology. 65:1024-1030
BackgroundThe Sysmex XN haematology instrument performs automatic reflex testing, depending on sample results. A nucleated red blood cell (NRBC) count is provided on all samples. The instrument has a smaller footprint (34%) than previous Sysmex XE an
Autor:
Hannah Cohen, I Longair, Chris Gardiner, Samuel J. Machin, Laura E. Green, Anthony Lawrie, J. Hills
Publikováno v:
Thrombosis Research. 130:110-114
Patients receiving warfarin are at increased risk of bleeding when their International Normalised Ratio (INR)4.5. Although not standardised above 4.5 the INR is measured in over-anticoagulated patients, consequently we have examined the reliability o
Publikováno v:
International Journal of Laboratory Hematology. 33:357-368
Summary Introduction: Performance of the Celltac F haematology analyser (MEK-8222) which provides 22 parameters, including a 5-part differential, was compared with the Sysmex XE-2100. Methods: 242 EDTA samples were investigated. Differential results
Publikováno v:
Journal of Thrombosis and Haemostasis. 7:529-536
Evidence for cardiac involvement in thrombotic thrombocytopenic purpura (TTP) is uncommonly described.We retrospectively reviewed 41 patients assessing troponin T as a marker for cardiac involvement in acute TTP with clinical symptoms, electrocardiog
Autor:
Carol Briggs, K. Thwaite, D. Romanin, I Longair, Samuel J. Machin, V. Thavaraja, R. Mills, A. Foster, M. Slavik
Publikováno v:
International Journal of Laboratory Hematology. 31:48-60
Automation of differentials is desirable for economic and time-saving reasons. Over the last 20 years, automated imaging processes have started to be introduced where stained blood films are scanned by a computer-driven microscope and leucocytes clas
Publikováno v:
American Journal of Clinical Pathology. 129:500-504
The SmartCheck INR (Unipath, Bedford, England) is a point-of-care device for professional and patient self-monitoring of oral anticoagulant therapy. It measures the international normalized ratio (INR) and assesses test strip integrity, temperature,
Publikováno v:
British Journal of Haematology. 132:598-603
Several studies suggest that patient self-management (PSM) may improve the quality of oral anticoagulation therapy as measured by time spent within the international normalised ratio (INR) target range. We performed a prospective randomised control t
Publikováno v:
International journal of laboratory hematology. 33(4)
Performance of the Celltac F haematology analyser (MEK-8222) which provides 22 parameters, including a 5-part differential, was compared with the Sysmex XE-2100.242 EDTA samples were investigated. Differential results from both instruments were compa
Publikováno v:
Journal of Clinical Pathology
Background: Patient self-monitoring (PSM) of oral anticoagulation therapy (OAT) can improve anticoagulant control, but poor uptake and high dropout rates have prompted suggestions that PSM is suitable for only a minority of patients in the UK. Aims: