Zobrazeno 1 - 10
of 11
pro vyhledávání: '"I Iu Skuchas"'
Publikováno v:
Kardiologiia. 30(5)
The analysis of the data available in the literature has shown that bipolar pacing systems are promising. The paper indicates that the first samples of a Soviet bipolar electrode have been made and tested in the laboratory setting. It also raises whe
Autor:
A S, Dumchus, E K, Shirvinskas, I Iu, Skuchas, S Iu, Gedraĭtis, A A, Krakovskiĭ, V S, Chekanov
Publikováno v:
Grudnaia i serdechno-sosudistaia khirurgiia. (1)
The article deals with the description and analysis of the first two operations undertaken for the development of the method and the first clinical use of extended myoventriculoplasty with programmed cardiosynchronized electroneurostimulation. The au
Publikováno v:
Bulletin of Experimental Biology and Medicine. 99:360-362
A pacing electrode with a porous surface saturated with glucocorticoids has been designed in order to diminish the pacing threshold of the heart. The data obtained in animal studies show that saturation of the electrode with dexamethasone before impl
Publikováno v:
Meditsinskaia tekhnika. (6)
The deficiencies of current electrocardiostimulation equipment are being discussed on the basis of analysis of cases with the device implantation. The authors propose changing the shape of the electrocardiostimulator so, that the frame of the device
Publikováno v:
Klinicheskaia meditsina. 64(10)
[Main recommendations for improvement of endocardial electrodes for continuous electric stimulation]
Publikováno v:
Meditsinskaia tekhnika. (1)
Publikováno v:
Biulleten' eksperimental'noi biologii i meditsiny. 100(10)
The authors present the data of the histological structure of the dog heart tissue adjacent to the electrode tip following a ten-month period of electrical stimulation by means of an implanted graphited porous endocardial electrode and a pacemaker of
Publikováno v:
Fiziologicheskii zhurnal SSSR imeni I. M. Sechenova. 71(10)
Publikováno v:
Meditsinskaia tekhnika. (3)
Endocardial electrodes of original construction are described: with polyhedral head, with split contact head and crescent-shaped one. These electrodes proved to be more efficient than that with spherical or cylindrical contact head with equal contact
Publikováno v:
Biulleten' eksperimental'noi biologii i meditsiny. 99(3)
A pacing electrode with a porous surface saturated with glucocorticoids has been designed in order to diminish the pacing threshold of the heart. The data obtained in animal studies show that saturation of the electrode with dexamethasone before impl