Zobrazeno 1 - 10
of 14
pro vyhledávání: '"Hyeok Jin Yun"'
Publikováno v:
Korean Journal of Soil Science and Fertilizer. 55:563-569
Autor:
Dong-Keun Jeong, Hyeok-Jin Yun, Si-Ho Park, Myoung-Ho Kim, Myung-Hyo Ryu, Ju-Won Baek, Ho-Sung Kim
Publikováno v:
Electronics; Volume 11; Issue 19; Pages: 3092
This paper presents a 13.2 kV class 3-phase solid-state transformer (SST) based on EtherCAT communication. In general, when the structure of the unit module is determined, the number of high-frequency isolated transformers (HFIT) is also proportional
Autor:
Hyeok-Jin Yun, Seong-Woo Kang, Ean-Gyu Han, Kown-Young Jung, Raegeun Park, Tae-Koo Kang, Dae-Hyeon Jeon, Ji-Hoon Park
Publikováno v:
Journal of Institute of Control, Robotics and Systems. 26:279-294
Publikováno v:
Energies, Vol 11, Iss 4, p 928 (2018)
One of the main disadvantages of the multi-level solid-state transformer (SST) system is the voltage imbalance on the output of the rectifier modules. This voltage imbalance can be caused by parameter mismatch of the active and passive components, di
Externí odkaz:
https://doaj.org/article/d5de4a9176954ab3a0b3306bd36754fc
Publikováno v:
2019 IEEE Third International Conference on DC Microgrids (ICDCM).
In this paper, in order to supply a bipolar ± 750 V DC for LVDC distribution system, a 13.2kV AC / 150kVA solid state transformer (SST) was proposed. This prototype SST was installed in Go-Chang which is DC distribution test site in Korea. The desig
Publikováno v:
Energies, Vol 11, Iss 4, p 928 (2018)
Energies; Volume 11; Issue 4; Pages: 928
Energies; Volume 11; Issue 4; Pages: 928
One of the main disadvantages of the multi-level solid-state transformer (SST) system is the voltage imbalance on the output of the rectifier modules. This voltage imbalance can be caused by parameter mismatch of the active and passive components, di
Publikováno v:
2017 19th European Conference on Power Electronics and Applications (EPE'17 ECCE Europe).
In this paper, a simple voltage balance controller for a SST using cascaded H-bridge rectifiers is proposed to deal with voltage unbalance problem of DC-links. The tolerance of parameters on DC-DC stage, which consists of parallel-connected DAB conve
Publikováno v:
2017 19th European Conference on Power Electronics and Applications (EPE'17 ECCE Europe).
This paper proposes a DC-bus signaling (DBS) method for a power management in a DC microgrid. In order to autonomously increase its reliability and response speed. As opposed to a centralized power management system, which needs communication among t
Autor:
Myoungho Kim, Juyong Kim, Ju-Won Baek, Hyeok-Jin Yun, Hee-Je Kim, Dong-Keun Jeong, Ho Sung Kim
Publikováno v:
Electronics, Vol 7, Iss 5, p 62 (2018)
Electronics; Volume 7; Issue 5; Pages: 62
Electronics; Volume 7; Issue 5; Pages: 62
This paper presents the implementation of a single-phase solid-state transformer (SST) for the interface between a 13.2 kV medium voltage alternative current (MVAC) network and a 750 V bipolar DC distribution. The SST has ten cascaded subunits in con
Publikováno v:
AIM
A modular multi-level converter (MMC) is composed of many sub-modules (SMs). Each SM needs a power supply to drive insulated-gate bipolar transistor (IGBT) and control power. The MMC system has a power of 100MW, a dc link voltage of 250kV, and a tota