Zobrazeno 1 - 10
of 23
pro vyhledávání: '"Huib L. Vader"'
Autor:
Arjen-Kars Boer, Johannes M.W. van den Ouweland, Huib L. Vader, Judith M A Emmen, Jos P.M. Wielders
Publikováno v:
Clinical Chemistry and Laboratory Medicine (CCLM). 50:1969-1972
Background: Measurement of serum 25-hydroxyvitamin D [25(OH)D] is used to assess vitamin D status. We evaluated the analytical performance of a new automated assay, Elecsys Vitamin D Total (Roche Diagnostics, Mannheim, Germany), based on competitive
Publikováno v:
American Journal of Clinical Pathology. 133:331-335
The Clinical and Laboratory Standards Institute (CLSI) recently abandoned its recommendation for drawing a discard tube when performing a prothrombin time (PT)/international normalized ratio (INR) or an activated partial thromboplastin time (APTT). B
Publikováno v:
Clinical Chemistry and Laboratory Medicine, 43(5), 531-535. Walter de Gruyter GmbH
We observed 30% discrepancy between liquid chemistry and dry chemistry analysers for the determination of total bilirubin in human adult serum samples, which were consistent with a 20% overestimation and 10% underestimation relative to a Jendrassik-G
Publikováno v:
Clinical Chemistry and Laboratory Medicine, 42(12), 1401-1407. Walter de Gruyter GmbH
Clinical Chemistry and Laboratory Medicine, 42, 12, pp. 1401-7
Clinical Chemistry and Laboratory Medicine, 42, 1401-7
Clinical Chemistry and Laboratory Medicine, 42, 12, pp. 1401-7
Clinical Chemistry and Laboratory Medicine, 42, 1401-7
Standardization of laboratory results allows for the use of common reference intervals and can be achieved via calibration of field methods with secondary reference materials. These harmonization materials should be commutable, i.e., they produce ide
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::0a322758508608c81b52acf88cee2641
https://research.tue.nl/nl/publications/3f2c0367-ccca-4ac2-9cb6-fe764d57ead7
https://research.tue.nl/nl/publications/3f2c0367-ccca-4ac2-9cb6-fe764d57ead7
Autor:
Stanley F. Lo, Gerhard Schumann, Hans-Joachim Kytzia, F. Weber, Melanie Swartzentruber, Huib L. Vader, Basil T. Doumas
Publikováno v:
Clinical Biochemistry. 42:1328-1330
Objectives To assess the performance of the Doumas bilirubin reference method. Design and methods Ring trails using pooled patient specimens, a calibrator and human sera enriched with unconjugated bilirubin were analyzed in five laboratories using th
Publikováno v:
Clinical Chemistry. 41:510-514
The concentration of von Willebrand factor (vWf) in patients' plasma can be determined by measuring the ristocetin cofactor activity (vWf R:Co). However, this vWf R:Co assay is time consuming, which limits its routine use. Several commercial vWf R:Co
Autor:
Wouter M. Tiel Groenestege, Huib L. Vader, Marcel J.W. Janssen, Hong N. Bui, Paul P.C.A. Menheere, Joop ten Kate, Wytze P. Oosterhuis, Annemieke C. Heijboer
Publikováno v:
Groenestege, W M T, Bui, H N, ten Kate, J, Menheere, P P C A, Oosterhuis, W P, Vader, H L, Heijboer, A C & Janssen, M J W 2012, ' Accuracy of First and Second Generation Testosterone Assays and Improvement through Sample Extraction ', Clinical Chemistry, vol. 58, no. 7, pp. 1154-1156 . https://doi.org/10.1373/clinchem.2011.181735
Clinical chemistry, 58(7), 1154-1156. American Association for Clinical Chemistry Inc.
Clinical Chemistry, 58(7), 1154-1156
Clinical chemistry, 58(7), 1154-1156. American Association for Clinical Chemistry Inc.
Clinical Chemistry, 58(7), 1154-1156
To the Editor: The monitoring of antiandrogen treatment in patients with prostate cancer, investigation of hyperandrogenism in women, and evaluation of infants with ambiguous genitalia require accurate measurement of low testosterone concentrations.
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::87d9238f0329bc2cf433b5031d052a0d
https://research.vumc.nl/en/publications/4030195e-5be8-42a1-af15-07516f687633
https://research.vumc.nl/en/publications/4030195e-5be8-42a1-af15-07516f687633
Publikováno v:
Journal of Clinical Microbiology, 49(3), 1025-1029. American Society for Microbiology
The diagnosis of urinary tract infection (UTI) by urine culture is time-consuming and can produce up to 60 to 80% negative results. Fast screening methods that can reduce the necessity for urine cultures will have a large impact on overall turnaround
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::22c6c2a92187ca2737477ea1750ed3e0
https://research.tue.nl/nl/publications/1bf1a9c7-a7b7-48c5-b1ba-fdf58523a52e
https://research.tue.nl/nl/publications/1bf1a9c7-a7b7-48c5-b1ba-fdf58523a52e
Publikováno v:
American journal of clinical pathology. 133(2)
The Clinical and Laboratory Standards Institute (CLSI) recently abandoned its recommendation for drawing a discard tube when performing a prothrombin time (PT)/international normalized ratio (INR) or an activated partial thromboplastin time (APTT). B
Publikováno v:
Annals of clinical biochemistry. 45(Pt 6)
Background The principle of the erythrocyte sedimentation rate (ESR) as assessed by TEST 1 is different from that of Westergren-based methods. This could result in different influences on the tests by paraproteins. Methods We investigated the effect