Zobrazeno 1 - 9
of 9
pro vyhledávání: '"Hsuan-Wei Liu"'
Autor:
Hsuan-Wei Liu, Michael A. Becker, Korenobu Matsuzaki, Randhir Kumar, Stephan Götzinger, Vahid Sandoghdar
Publikováno v:
ACS Nano. 16:12831-12839
Scanning probe microscopes scan and manipulate a sharp tip in the immediate vicinity of a sample surface. The limited bandwidth of the feedback mechanism used for stabilizing the separation between the tip and the sample makes the fragile nanoscopic
Publikováno v:
ACS Photonics. 8:1508-1521
Publikováno v:
ACS Nano. 11:7674-7678
We report on the manipulation of a plasmonic nanoantenna in an aqueous solution using an electrostatic trap created between a glass nanopipette and a substrate. By scanning a trapped gold nanosphere in the near field of a single colloidal quantum dot
Autor:
Bo-Tsun Chou, Sheng-Di Lin, Kuang Jen Lai, Jer-Shing Huang, Fan Cheng Lin, Shi Wei Lin, Hsuan Wei Liu, Jau Yang Wu
Publikováno v:
ACS Nano. 9:3875-3886
Aluminum, as a metallic material for plasmonics, is of great interest because it extends the applications of surface plasmon resonance into the ultraviolet (UV) region and is superior to noble metals in natural abundance, cost, and compatibility with
Publikováno v:
Scopus-Elsevier
Semiconductor quantum dots are useful emitters in various contexts. They are, for example, a bright source of photons because of the possibility to generate multiple excitons within one quantum dot and subsequently obtain the emission of multiple pho
Autor:
Matthew R. Buck, Simon Vassant, Jennifer A. Hollingsworth, Stephan Götzinger, Korenobu Matsuzaki, Hsuan-Wei Liu, Silke Christiansen, Anke Dutschke, Björn Hoffmann, Xue-Wen Chen, Vahid Sandoghdar
Publikováno v:
Scientific Reports
Scientific Reports, 2017, 7, pp.42307. ⟨10.1038/srep42307⟩
Scientific Reports, 2017, 7, pp.42307. ⟨10.1038/srep42307⟩
Multiexcitonic transitions and emission of several photons per excitation comprise a very attractive feature of semiconductor quantum dots for optoelectronics applications. However, these higher-order radiative processes are usually quenched in collo
Publikováno v:
Biophysical Journal. 114:354a-355a
Publikováno v:
ATS
The cell-aware test (CAT) methodology was previously proposed to target cell-internal faults that cannot be easily detected by gate-level stuck-at fault (SAF) patterns generated by conventional ATPG. It was shown to reduce the defect level on CMOS-ba
Autor:
Hsuan wei,Liu, 劉宣緯
100
This note presents an approach to analyze the stability of the closed-loop system for digital controller implementations by minimizing a measure synthesized by the magnitude and phase sensitivities of eigenvalues. First, uncertainties of the
This note presents an approach to analyze the stability of the closed-loop system for digital controller implementations by minimizing a measure synthesized by the magnitude and phase sensitivities of eigenvalues. First, uncertainties of the
Externí odkaz:
http://ndltd.ncl.edu.tw/handle/78732815136048549585