Publikováno v:
IEEE Electrical Insulation Magazine. 36:19-30
Large power generators, especially hydropower generators with a few hundred megawatts power and a few ten kV voltages, have high inertial power while operating, so they must not only withstand the operating torques and forces during operation, but al
Publikováno v:
IEEE Transactions on Dielectrics and Electrical Insulation. 25:1644-1650
The acoustic emission signals produced by discharges of a point-plane electrode on the surface (surface discharge) of different oil-impregnated aramid pressboards are detected by a 150 kHz acoustic emission sensor mounted on the outside of the experi
Publikováno v:
Lecture Notes in Electrical Engineering ISBN: 9783030316792
Partial discharge (PD) measurements are well-established under AC stress and their reproducibility is also quite good concerning partial discharge inception voltage (PDIV) and partial discharge extinction voltage (PDEV). Furthermore, correlation betw
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::170df63c9fef82e9c4e9238543da7b25
https://doi.org/10.1007/978-3-030-31680-8_144
https://doi.org/10.1007/978-3-030-31680-8_144
Publikováno v:
International Journal of Electrical Power & Energy Systems. 129:106899
Partial discharge (PD) measurement is a powerful tool for assessing the insulating system of power transformers. Among all the developed methods for PD monitoring, the electrical PD measurement is the only recommended method by the standard for the a
Publikováno v:
2018 IEEE International Conference on High Voltage Engineering and Application (ICHVE).
The destructive characteristics of partial discharges (PD) to insulation material are well known. PD in AC and DC stress has different behavior and characteristics. In the case of AC stress, phase-resolved partial discharge (PRPD) patterns, can be us
Publikováno v:
Electric Power Systems Research. 178:106034
When a Partial Discharge (PD) signal, which travels through a cross-bonded (CB) power cable system, reaches a CB joint, the signal not only continues its way on the defect phase but it also enters and propagates in the other faultless phases. For ana
Publikováno v:
IEEE Electrical Insulation Magazine. 30:34-41
The standard frequency response analysis (FRA) is not fully efficient for diagnostics of mechanical failures in power transformers. The article recommends that physical electrical parameters of the transformers should be analyzed in addition to suppo
Publikováno v:
IEEE Transactions on Dielectrics and Electrical Insulation. 20:2026-2034
To diagnose electrical and mechanical failures on the active part of power transformers efficiently, different state-of-the-art testing methods are recommended to be performed since transformers are complex devices. Measurement results can be equival
Publikováno v:
2016 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP).
Publikováno v:
2016 IEEE Electrical Insulation Conference (EIC).
Integration of a DC transmission system into the existing AC system is proposed in order to transmit more power from north to the south of Germany. Effects of such hybrid AC/DC fields on the dielectric characteristics of insulators, bushings and othe