Zobrazeno 1 - 10
of 58
pro vyhledávání: '"Hiroyuki Miyamaru"'
Autor:
Isao Murata, Shingo Tamaki, Sachie Kusaka, Indah Rosidah Maemunah, Fuminobu Sato, Hiroyuki Miyamaru, Shigeo Yoshida
Publikováno v:
Fusion Science and Technology. 79:465-475
Autor:
Taichi Hashimoto, Shingo Tamaki, Sachie Kusaka, Fuminobu Sato, Hiroyuki Miyamaru, Isao Murata
Publikováno v:
Radiation Measurements. 124:141-145
We developed three-dimensional (3D) dosimeters with radiophotoluminescence (RPL) material via fused-deposition modelling (FDM) 3D-printing technology. The 3D RPL dosimeter was a composite material consisting of polycaprolactone (PCL) resin and RPL gl
Autor:
Hiroyuki Miyamaru, Fuminobu Sato, Isao Murata, Shingo Tamaki, Sachie Kusaka, Taichi Hashimoto
Publikováno v:
Radiation Measurements. 124:137-140
We developed a long and bendable string-shaped photo-stimulated luminescence detector (PSLD) with a 2 mm diameter. This PSLD was made from a mixture of PSL particles, BaFBr:Eu2+, and transparent thermoplastic resin and fabricated using a filament ext
Publikováno v:
Progress in Nuclear Science and Technology. 6:126-129
Publikováno v:
Radiation Physics and Chemistry. 191:109870
A system for the real-time measurement of the visible light emission from and absorption by a material in an intense gamma-ray field was developed. A white light-emitting diode produces a visible light beam that passes through an irradiated specimen
Autor:
Shingo Tamaki, Isao Murata, Fuminobu Sato, Sachie Kusaka, Hiroyuki Miyamaru, Taichi Hashimoto
Publikováno v:
Radiation Measurements. 111:1-5
We developed a long and bendable string-shaped dosimeter, 2 mm in diameter. This string-shaped dosimeter, which was made from a mixture of silver-activated metaphosphate glass particles and polylactic acid resin, was fabricated with a filament extrud
Publikováno v:
Applied Radiation and Isotopes. 172:109698
A compact gamma-ray sensor composed of a cadmium sulfide (CdS) photoresistor and a small-sized cesium iodine doped thallium scintillator is introduced for intense gamma-ray monitoring. The sensor exhibits radiation-resistant ability and a linear outp
Publikováno v:
EPJ Web of Conferences, Vol 153, p 07015 (2017)
There are many benchmark experiments carried out so far with DT neutrons especially aiming at fusion reactor development. These integral experiments seemed vaguely to validate the nuclear data below 14 MeV. However, no precise studies exist now. The
Publikováno v:
Applied Radiation and Isotopes. 88:129-133
Author׳s group is carrying out development of BNCT-SPECT with CdTe device, which monitors the therapy effect of BNCT in real-time. From the design calculations, the dimensions were fixed to 1.5×2×30 mm 3 . For the collimator it was confirmed that
Autor:
Ryoichi Taniguchi, Shuichi Okuda, Takao Kojima, Hiroto Matsuura, Hiromoto Shimomura, Hiroyuki Miyamaru
Publikováno v:
Progress in Nuclear Science and Technology. 4:721-724
The response of the imaging plate (IP) as a two-dimensional irradiation dose monitor of high-energy electrons has been investigated. The Co-60 γ-ray irradiation facilities and the 16 MeV S-band electron linear accelerator (linac) in Radiation Resear