Zobrazeno 1 - 10
of 13
pro vyhledávání: '"Hiroyuki Kyushima"'
Autor:
M. H. Tanaka, Motohiro Suyama, Hiroyuki Kyushima, Yoshihiko Kawai, H. Kakuno, Hiroaki Aihara, M. Iwasaki, H. Nakayama, T. Abe, Masato Shiozawa, Akito Kusaka
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 579:42-45
We have developed the first complete large-aperture (13-inch diameter) hybrid photo-detector (HPD). The withstanding voltage problem has been overcome and we were able to attain an HPD operating voltage of +20 kV. Adoption of our newly developed back
Autor:
H. Kakuno, Masato Shiozawa, Hiroaki Aihara, Hiroyuki Kyushima, Akito Kusaka, Motohiro Suyama, M. Iwasaki, M. H. Tanaka, Yoshihiko Kawai, H. Nakayama, T. Abe
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 567:172-175
We have developed a 13-in. Hybrid Avalanche Photo-Detector (HAPD) for photosensors in next generation water Cherenkov type detectors. We study the performance of the HAPD and the results show good time resolution better than σ = 1 ns , good sensitiv
Autor:
Hiroaki Aihara, Motohiro Suyama, Yoshihiko Kawai, M. Iwasaki, Hiroyuki Kyushima, T. Abe, Masato Shiozawa, Keizo Kasimura, Hiroki Fujimori, Sogo Mineo, Manobu Tanaka, T. Uchida
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 623:279-281
This paper reports on the R&D status of a large-aperture Hybrid Avalanche Photo-Detector (HAPD). We have developed a 13-inch aperture HAPD and its readout system. The HAPD is a photo-detector expected to replace the photomultiplier tube (PMT) in next
Autor:
Hiroyuki Kyushima, Kimitsugu Nakamura
Publikováno v:
RADIOISOTOPES. 45:26-37
Autor:
Emiko Chino, Kimitsugu Nakamura, Keisuke Akiyama, Itaru Mizuno, Yoshihiro Ishigami, Hiroyuki Kyushima, Kazumasa Kato, Tsuneo Ihara, Takaaki Nagata, Tetsuji Matsuo
Publikováno v:
SPIE Proceedings.
We developed a high-sensitivity GaN photocathode that works in transmission mode. It has 40.9 % quantum efficiency at 310 nm wavelength. Conventional GaN photocathodes, both transmission mode and reflection mode, are made on a sapphire substrate usin
Autor:
J. Takeuchi, Masaki Mori, A. Suzuki, Hiroyuki Kyushima, Y. Ohashi, Toru Tanimori, K. Kaneyuki
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 329:299-313
The quality of the 20 in. photomultiplier tubes (Hamamatsu R1449) has been greatly improved over the required specifications for using them in the 50 000 ton imaging water Cherenkov detector, Super-Kamiokande. In particular, the resolution of the tim
Publikováno v:
2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC).
This paper reports on the R&D status of a large-aperture Hybrid Avalanche Photo-Detector (HAPD). We have developed a 13-inch aperture HAPD and its readout system. The HAPD is a photo detector expected to replace the photomultiplier tube (PMT) in next
Autor:
M. Iwasaki, M. H. Tanaka, Y. Kawai, Masato Shiozawa, H. Nakayama, H. Kakuno, Motohiro Suyama, T. Abe, Akito Kusaka, Hiroyuki Kyushima, H. Aihara
Publikováno v:
IEEE Nuclear Science Symposium Conference Record, 2005.
We have undertaken the development of a large scale hybrid photo-detector (HPD) and new readout system comprising an ASIC preamplifier, an analog memory cell (AMC) and an FPGA (DSP) which, together, are intended to be the next generation water Cheren
Autor:
S. Suzuki, H. Matsuura, Hiroyuki Kyushima, Michihiro Ito, Akira Atsumi, Y. Hasegawa, Koichiro Oba, H. Yokota, Junichi Takeuchi, Koji Nagura
Publikováno v:
1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference.
In spectroscopic analysis, radiation detection, and medical application fields, portable instruments requiring high accuracy and high sensitivity are being developed. Since conventional photomultiplier tube (PMT) envelopes are made of glass and are l
Autor:
Y. Watase, Y. Hasegama, H. Matsuura, Y. Yokota, Michihiro Ito, Koichiro Oba, Hiroyuki Kyushima, Akira Atsumi, Junichi Takeuchi
Publikováno v:
Conference Proceedings. 10th Anniversary. IMTC/94. Advanced Technologies in I & M. 1994 IEEE Instrumentation and Measurement Technolgy Conference (Cat. No.94CH3424-9).
The Metal Package PMT R5600U series, a size of 15 mm diameter and 10 mm height, has been developed. Its appearance is the same as TO-8 type solid state device and it has as high sensitivity and speed as a conventional PMT. There are two important key