Zobrazeno 1 - 10
of 22
pro vyhledávání: '"Hiroya Fukuda"'
Publikováno v:
Cureus
Deep learning is used to classify data into several groups based on nonlinear curved surfaces. In this paper, we focus on the theoretical analysis of deep learning using the rectified linear unit (ReLU) activation function. Because layers approximate
Autor:
Hiroya Fukuda, Yuko Takamatsu
Publikováno v:
IEEJ Transactions on Sensors and Micromachines. 139:85-86
Publikováno v:
Journal of Organometallic Chemistry. 798:375-383
A series of half-titanocenes containing 1,3-imidazolidin-2-iminato ligands of type, (tert-BuC5H4)TiCl2[1,3-R2(CH2N)2C N] [R = tBu (2a), cyclohexyl (Cy, 2b), C6H5 (2c), 2,6-Me2C6H3 (2d), 2,6-iPr2C6H3 (2e)] have been prepared and structures of 2a–d h
Publikováno v:
RSC Advances. 5:64503-64513
A series of (pentamethylcyclopentadienyl)titanium(IV) dichloride complexes containing 1,3-imidazolidin-2-iminato ligands of type, Cp*TiCl2[1,3-R2(CH2N)2CN] [R = tBu (1a), cyclohexyl (Cy, 1b), C6H5 (1c), 2,6-Me2C6H3 (1d), 2,6-iPr2C6H3 (1e)] have been
Autor:
Satoshi Nagai, Hiroya Fukuda
Publikováno v:
IEEJ Transactions on Electronics, Information and Systems. 138:635-636
Autor:
Hiroya Fukuda, Alexandra G. Trambitas, Wannida Apisuk, Matthias Tamm, Kotohiro Nomura, Boonyarach Kitiyanan
Publikováno v:
Journal of Molecular Catalysis A: Chemical. :501-511
Ethylene copolymerization with 1-hexene, styrene using half-titanocenes containing 1,3-dialkyl- and 1,3-diarylimidazolin-2-iminato ligands, Cp′TiCl2[1,3-R2(CHN)2C N] [Cp′ = Cp (1), tBuC5H4 (2); R = tBu (a), 2,6-iPr2C6H3 (b)], have been explored i
Autor:
Irfan Saeed, Shohei Katao, Hyun Joon Kim, Michiya Fujiki, Kotohiro Nomura, Hiroya Fukuda, Dong-Hyun Kim
Publikováno v:
Macromolecules. 44:1986-1998
A series of half-titanocenes containing pyrazolato ligands, Cp′TiCl2(3,5-R2C3HN2) (1a−d, 2a−c, 3a−c) [Cp′ = Cp (1), Cp* (2), tert-BuC5H4 (tert-BuCp, 3); R = H (a), Me (b), iPr (c), Ph (d)], have been employed as the catalyst precursors for
Publikováno v:
IEEJ Transactions on Industry Applications. 123:188-195
This paper deals the digital optimal current control scheme to improve MRI (Magnetic Resonant Imaging) Gradient-Magnetic Coil (GC) current control implementation. The GC current needs high precision control specifications so as to take clear images w
Publikováno v:
IEEJ Transactions on Industry Applications. 123:894-902
This paper deals with a digital control scheme of multiple paralleled high frequency switching current amplifier with four-quadrant chopper for generating gradient magnetic fields in MRI (Magnetic Resonance Imaging) systems. In order to track high pr
Autor:
Ryo Ikeda, Hiroya Fukuda
Publikováno v:
The Proceedings of the Symposium on sports and human dynamics. 2011:576-578