Zobrazeno 1 - 10
of 20
pro vyhledávání: '"Hilliary M. Killer"'
Autor:
Espeed Khoshbin, Giles J. Peek, Anthony E. W. Dux, Hilliary M. Killer, Richard K. Firmin, Andrzej W. Sosnowski
Publikováno v:
Perfusion. 22:15-21
Introduction: The inflammatory response caused by extracorporeal membrane oxygenation (ECMO) is clearly visible within the first 24 h of cannulation. The inflammatory process affects all areas of the lung, even areas previously spared by the primary
Autor:
Giles J. Peek, Suneel Pooboni, Espeed Khoshbin, Andrzej W. Sosnowski, David Machin, Hilliary M. Killer, Claire Westrope, Richard K. Firmin
Publikováno v:
Perfusion. 20:129-134
Objective: To review the performance of polymethyl pentene versus silicone oxygenators in terms of efficiency in priming and oxygenation, oxygenator resistance, requirements for coagulation proteins and consumption of blood products, for neonatal ext
Autor:
Andrzej W. Sosnowski, Espeed Khoshbin, David Machin, Richard K. Firmin, Hilliary M. Killer, Giles J. Peek
Publikováno v:
Perfusion. 20:177-181
Objective: To report a single case of oxygenator failure caused by clot embolism originating from the bladder; and to discuss some preventative options. Case report: A 2.5 kg neonate with a diagnosis of influenza A received veno-arterial (V / A) extr
Autor:
Hitesh Pandya, Hilliary M. Killer, Richard K. Firmin, Neil Roberts, Claire Westrope, Suneel Pooboni, David R. Jenkins
Publikováno v:
Pediatric Pulmonology. 36:310-315
Severe B. pertussis infection in infants is characterized by severe respiratory failure, pulmonary hypertension, leukocytosis, and death. This retrospective case analysis highlights the course and outcome of severe B. pertussis infection treated with
Publikováno v:
Perfusion. 17:125-132
We measured the response of fresh heparinized human blood to recirculation through circuits made of LVA (Portex Industries, Hythe, Kent, UK), SRT (Rehau UK, Langley, Slough, UK) and Tygon® S-65-HL (Norton Performance Plastics, Corby, Northants, UK),
Autor:
Giles J. Peek, Elaine D. Woodland, David Upton, Graham Lawson, Hussain Mulla, Hilliary M. Killer, Richard K. Firmin
Publikováno v:
Current Therapeutic Research. 61:838-848
Background: It has been observed that neonatal patients receiving extracorporeal membrane oxygenation (ECMO) require larger doses of sedatives than do non-ECMO patients to achieve similar levels of sedation. Objective: The purpose of this study was t
Publikováno v:
Perfusion. 15:457-466
During the prolonged roller pump use of extracorporeal membrane oxygenation (ECMO), tubing wear generates spallation. The spallation performance of Tygon® S-65-HL was measured and compared with a potential new ECMO tubing, LVA (Portex 800-500-575).
Publikováno v:
Perfusion. 14:443-452
Little is known about the mechanical forces acting on extracorporeal circuit tubing with prolonged roller pump use during extracorporeal membrane oxygenation (ECMO). We examined the time to tubing rupture of three different materials during actual ro
Autor:
Hilliary M. Killer, Giles J. Peek, Richard Scott, Richard K. Firmin, Derek Forbes, Martin A. Jarvis, Shyam Kolvekar
Publikováno v:
ASAIO Journal. 45:488-495
The sheep has been the standard laboratory animal for extracorporeal membrane oxygenation (ECMO) research for many years and has proven to be an invaluable and reliable model. However the coagulation system of the sheep is significantly different fro
Autor:
Richard K. Firmin, Hilliary M. Killer
Publikováno v:
Perfusion. 14:291-297