Background: Proliferative diabetic retinopathy (PDR) is a serious sight-threatening disease, and half of the patients with high-risk PDR can develop legal blindness within 5 years, if left untreated. This study was aimed at comparing panretinal photo
Distribution of angle lambda and pupil offset as measured by combined Placido Scheimpflug Topography
Publikováno v:
International Ophthalmology. 43:121-130
Background Angle lambda is the angle between the pupillary axis and the line of sight. It is important for accurate centration during anterior segment surgery. The purpose of this study is to identify the distribution of angle lambda and pupil center
Publikováno v:
Optometry and Vision Science. 99:580-588
This study obtained normative database for angle κ using Orbscan 3. The average angle κ values were 2.3 ± 1.34° in the whole sample, 2.23 ± 1.36° in myopic eyes, and 3.3 ±1.5° in hyperopic eyes. This is very important to optimize refractive s
Publikováno v:
Clinical Ophthalmology. 14:3801-3810
Purpose This study aims to assess the intra-operator repeatability and correlation of the Pentacam HR (device 1) and Sirius (device 2) in measuring anterior segment parameters and to evaluate the agreement of their readings and therefore their interc
Publikováno v:
International Ophthalmology. 41:629-638
Detecting the accuracy of various posterior elevation (PE) indices of Pentacam HR, and correlating them with some possibly related factors or parameters, in a cohort with early keratoconus (KC).A cross sectional study that was conducted at Eye World
Autor:
Mohamed Omar Yousif, Hesham Mohamed Gharieb, Noha Abdelsadek Alaarag, Abdelrhman Shams, Rania Serag Elkitkat
Publikováno v:
Clinical Ophthalmology. 14:2203-2210
Purpose To investigate the relationship between corneal astigmatism and corneal image quality parameters (i.e., root mean square [RMS] of some major corneal higher order aberrations [HOAs] "namely RMS of coma aberrations, RMS of trefoil aberrations,
Publikováno v:
International Ophthalmology. 40:1759-1764
To assess the agreement between Orbscan 3, Pentacam HR and ultrasound pachymetry (Palm Scan AP 2000) in measuring central corneal thickness. Prospective observational cross-sectional study of ninety-two eyes of 48 patients with normal corneas was con
Publikováno v:
Cornea. 39:649-653
Purpose Many topography/tomography devices are available, and their interchangeable use is frequently questioned. This study aimed to compare the analogous indices of Orbscan 3 and Pentacam HR to detect whether the interchangeable use of the 2 device
Publikováno v:
Clinical Ophthalmology. 13:2477-2488
Purpose To analyze the effectiveness and stability of the refractive, topographic and visual outcomes of the standard cross-linking (SCXL) in keratoconus (KC) management. Patients and methods This study was designed as a retrospective non-comparative
Publikováno v:
European journal of ophthalmology. 32(4)
Purpose To determine the normative and the cut-off values of various indices available in the MS 39 Anterior Segment Optical Coherence Tomography (MS-39 AS-OCT) for keratoconus (KC) diagnosis, and to detect the accuracy of the variable available para