Zobrazeno 1 - 10
of 15
pro vyhledávání: '"Hermann Monstadt"'
Autor:
Tim Lenz-Habijan, Pervinder Bhogal, Catrin Bannewitz, Ralf Hannes, Hermann Monstadt, Andreas Simgen, Ruben Mühl-Benninghaus, Wolfgang Reith, Hans Henkes
Publikováno v:
European Radiology Experimental, Vol 3, Iss 1, Pp 1-9 (2019)
Abstract Background Flow diverters (FDs) are widely used in the treatment of intracranial aneurysms, but the required medication increases the risk of haemorrhagic complications and limits their use in the acute setting. Surface modified FDs may limi
Externí odkaz:
https://doaj.org/article/d146d3c373e74766946850a16437435f
Autor:
Rosa Martínez Moreno, Pervinder Bhogal, Tim Lenz-Habijan, Catrin Bannewitz, Adnan Siddiqui, Pedro Lylyk, Ralf Hannes, Hermann Monstadt, Hans Henkes
Publikováno v:
European Radiology Experimental, Vol 3, Iss 1, Pp 1-13 (2019)
Abstract Background Flow-diverter stents (FDSs) have revolutionised the treatment of intracranial aneurysms. However, associated dual antiplatelet treatment is mandatory. We investigated the biocompatibility of three proprietary antithrombogenic coat
Externí odkaz:
https://doaj.org/article/e311016bd1fd4679aa8c95249afa8ee3
Autor:
Thomas Jackwerth-Rice, Dominic Böcker, Matthias Derse, Kirsten Elsebrock, Thomas Jehnichen, Thomas Kley, Bernd Kriegesmann, Christian Lerch, Hermann Monstadt, Peter Weiß, Marius Wernet
Publikováno v:
Digitalisierung der Arbeitswelt im Mittelstand 1 ISBN: 9783662648025
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::29641b7616e7a171899fd4eeb23d628e
https://doi.org/10.1007/978-3-662-64803-2_4
https://doi.org/10.1007/978-3-662-64803-2_4
Autor:
Pervinder Bhogal, Beate E. Kehrel, Hans Henkes, Catrin Bannewitz, Hermann Monstadt, Martin Brodde, M. Aguilar Pérez, K. Gromann, Tim Lenz-Habijan
Publikováno v:
Cardiovascular and Interventional Radiology
Background Dual antiplatelet therapy is a pre-requisite for flow diverter (FD) implantation. The purpose of this study was to assess the thrombogenicity of the p48 FD, coated with the newly developed phenox Hydrophilic Polymer Coating (p48_HPC, pheno
Autor:
Martin Brodde, Hermann Monstadt, Ralf Hannes, Hans Henkes, Catrin Bannewitz, Tim Lenz-Habijan, Pervinder Bhogal, Beate E. Kehrel
Publikováno v:
Interv Neuroradiol
Objectives The implantation of flow diverters, or stents in general, necessitates the use of dual anti-platelet treatment with typical regimes including aspirin and a P2Y12 inhibitor. This carries an inherent risk of haemorrhage. We sought to compare
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::c1b1ab1449aa8744cdf836a047c4e4ef
https://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&origin=inward&scp=85084609583
https://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&origin=inward&scp=85084609583
Autor:
Hermann Monstadt, Pedro Lylyk, Tim Lenz-Habijan, Marcus Peters, Hans Henkes, Christina Sengstock, Marta Aguilar Pérez, Catrin Bannewitz, Pervinder Bhogal, Oliver Ganslandt
Publikováno v:
Interventional Neuroradiology
Background: Stent-assisted coiling and extra-saccular flow diversion require dual anti-platelet therapy due to the thrombogenic properties of the implants. While both methods are widely accepted, thromboembolic complications and the detrimental effec
Autor:
Adnan H. Siddiqui, Ralf Hannes, Hermann Monstadt, Pervinder Bhogal, Pedro Lylyk, Tim Lenz-Habijan, Rosa Martinez Moreno, Hans Henkes, Catrin Bannewitz
Publikováno v:
European Radiology Experimental
European Radiology Experimental, Vol 3, Iss 1, Pp 1-13 (2019)
European Radiology Experimental, Vol 3, Iss 1, Pp 1-13 (2019)
BACKGROUND: Flow-diverter stents (FDSs) have revolutionised the treatment of intracranial aneurysms. However, associated dual antiplatelet treatment is mandatory. We investigated the biocompatibility of three proprietary antithrombogenic coatings app
Autor:
Hans Henkes, Sebastian Weber, Tim Lenz-Habijan, Hermann Monstadt, Volker Trösken, Werner Theisen, Catrin Bannewitz, S. Siebert, Jonathan Lentz, Marcus Peters
Publikováno v:
Coatings, Vol 11, Iss 93, p 93 (2021)
Coatings
Volume 11
Issue 1
Coatings
Volume 11
Issue 1
Bare metal endovascular implants pose a significant risk of causing thrombogenic complications. Antithrombogenic surface modifications, such as phenox&rsquo
s &ldquo
Hydrophilic Polymer Coating&rdquo
(pHPC), which was originally develo
s &ldquo
Hydrophilic Polymer Coating&rdquo
(pHPC), which was originally develo
Autor:
Hermann Monstadt, Albrecht Bufe, Marcus Peters, Pervinder Bhogal, Hans Henkes, Catrin Bannewitz, Tim Lenz-Habijan, Rosa Martinez Moreno
Publikováno v:
Cardiovascular and Interventional Radiology
Background: Endovascular stents and flow diverter stents (FDS) have revolutionized the treatment of intradural aneurysms; however, the need for dual anti-platelet treatment (DAPT) limits their use and can cause additional issues. Therefore, there is
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::b88ea64e6449c250e6890b7a33f0b829
https://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&origin=inward&scp=85050545227
https://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&origin=inward&scp=85050545227
Autor:
Alexander Knickmeier, Stefanie Lauterbach, Hermann Monstadt, Holger Pracht, Thomas Kley, Ralf Hannes, Minela Balic, Birgit Ottensmeier, Bernd Kriegesmann
Publikováno v:
Kompetenzentwicklung in analogen und digitalisierten Arbeitswelten ISBN: 9783662549551
Dass Kompetenzentwicklung als Innovationstreiber gelten kann, stellt einen disziplinenubergreifenden Konsens dar. Investitionen in die „Human Side of Innovation“ werden jedoch in der Praxis immer wieder vernachlassigt. Dieses Spannungsfeld wird i
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::8bb07dd9041372dc0a6c30327e9ac172
https://doi.org/10.1007/978-3-662-54956-8_8
https://doi.org/10.1007/978-3-662-54956-8_8