Zobrazeno 1 - 10
of 10
pro vyhledávání: '"Herbert Hoedlmoser"'
Autor:
N Patrick Mayr, Gunther Wiesner, Angela Kretschmer, Johannes Brönner, Herbert Hoedlmoser, Oliver Husser, Albert M Kasel, Rüdiger Lange, Peter Tassani-Prell
Publikováno v:
PLoS ONE, Vol 14, Iss 1, p e0210872 (2019)
OBJECTIVE:Transfemoral Transcatheter Aortic Valve Implantation (TAVI) has become a standard therapy for patients with aortic valve stenosis. Fluoroscopic imaging is essential for TAVI with the anesthesiologist's workplace close to patient's head side
Externí odkaz:
https://doaj.org/article/949fb852e487491480f49c170aa3be6d
Autor:
Ronen Sircar, Ulrich Hubbe, Ioannis Vasilikos, Johannes Brönner, Yashar Naseri, Herbert Hoedlmoser, Jan-Helge Klingler, Roland Roelz, Christoph Scholz, Marie T. Krüger, Florian Volz, Marc Hohenhaus
Publikováno v:
Clinical Spine Surgery: A Spine Publication. 34:E211-E215
Study design A randomized controlled trial. Objective To compare the radiation exposure with the scrub nurse, assistant surgeon, and anesthetist during minimally invasive transforaminal lumbar interbody fusion using conventional 2-dimensional (2D) fl
Autor:
Marie T. Krüger, Herbert Hoedlmoser, Johannes Brönner, Ulrich Hubbe, Jan-Helge Klingler, Marc Hohenhaus, Ronen Sircar, Florian Volz, Christoph Scholz, Yashar Naseri
Publikováno v:
Spine. 46:1-8
Study design Randomized controlled trial. Objective The aim of this study was to compare the dosemetrically determined radiation exposure of surgeon and patient during minimally invasive transforaminal lumbar interbody fusion (MIS TLIF) using convent
Autor:
Jan-Helge Klingler, Yashar Naseri, Peter C. Reinacher, Herbert Hoedlmoser, Horst Urbach, Marc Hohenhaus
Publikováno v:
The spine journal : official journal of the North American Spine Society. 22(9)
Intraoperative CT imaging is becoming increasingly used, but often little attention is paid to the underlying radiation exposure to the patient. This work showed that the dosimetrically assessed radiation exposure for cervical and lumbar 3D scans wit
Autor:
Silvan, Jungi, Marius, Ante, Philipp, Geisbüsch, Herbert, Hoedlmoser, Philip, Kleinau, Dittmar, Böckler
Publikováno v:
Jungi, S; Ante, M; Geisbüsch, P; Hoedlmoser, H; Kleinau, P; Böckler, D (2022). Protected and Unprotected Radiation Exposure to the Eye Lens during Endovascular Procedures in Hybrid Operating Rooms. European journal of vascular and endovascular surgery, 64(5), pp. 567-572. Elsevier 10.1016/j.ejvs.2022.06.016
OBJECTIVE Radiation cataract has been observed at lower doses than previously thought. Therefore, the annual limit for equivalent dose to the eye lens has been reduced from 150 to 20mSv. This study evaluates radiation exposure to the eye lens of oper
Autor:
Johannes Brönner, Ulrich Hubbe, Yashar Naseri, Florian Volz, Marie T. Krüger, Marc Hohenhaus, Jürgen Beck, Ralf Watzlawick, Herbert Hoedlmoser, Roland Roelz, Jan-Helge Klingler, Christoph Scholz
Publikováno v:
Global Spine J., DOI: 10.1177/21925682211039497 (2021)
Study Design: Prospective cohort study. Objectives: The purpose of this prospective study was to evaluate a protocol for radiation-sparing kyphoplasty by assessing dosemetrically recorded radiation exposures to both patient and surgeon. Methods: This
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::adf8cb35ab4d9dae8f61b900221a0adc
https://push-zb.helmholtz-muenchen.de/frontdoor.php?source_opus=63048
https://push-zb.helmholtz-muenchen.de/frontdoor.php?source_opus=63048
Autor:
Matthias Greiter, Martin Schmid, Herbert Hoedlmoser, Hans-Erik Källman, Andreas Österlund, Wilfried Drohn
Publikováno v:
Acta radiologica (Stockholm, Sweden : 1987). 63(1)
Background The radiation dose to staff performing endoscopic retrograde cholangiopancreatography (ERCP) is not negligible. Purpose To evaluate the shielding effect of a table-suspended lower-body radiation shield for the positions in the room occupie
Publikováno v:
The spine journal : official journal of the North American Spine Society. 21(8)
The annual limit value for the eye lens dose for occupationally exposed personnel has recently been considerably reduced from 150mSv to 20mSv. We have therefore re-evaluated the effectiveness of radiation protection measures (lead glass goggles, mobi
Autor:
Jan-Helge, Klingler, Christoph, Scholz, Marie T, Krüger, Yashar, Naseri, Florian, Volz, Marc, Hohenhaus, Johannes, Brönner, Herbert, Hoedlmoser, Ronen, Sircar, Ulrich, Hubbe
Publikováno v:
Spine. 46(1)
Randomized controlled trial.The aim of this study was to compare the dosemetrically determined radiation exposure of surgeon and patient during minimally invasive transforaminal lumbar interbody fusion (MIS TLIF) using conventional 2D fluoroscopy (FL
Autor:
John Mellerio, David H. Sliney, Gerald Sonneck, Frank Rattay, Herbert Hoedlmoser, Karl Schulmeister
Publikováno v:
SPIE Proceedings.
In laser safety, dose-response curves describe the probability for ocular injury as a function of ocular energy, and are often used to quantify the risk for ocular injury given a certain level of exposure to laser radiation. In principal, a dose-resp