Isabelle Saniour, Fraser Robb, Olivier Beuf, Simon A. Lambert, Kevin Tse Ve Koon, Hamza Raki, Henri Souchay
Publikováno v:
IEEE Sensors Journal
IEEE Sensors Journal, 2020, 20 (18), pp.10511-10520. ⟨10.1109/JSEN.2020.2995055⟩
IEEE Sensors Journal, Institute of Electrical and Electronics Engineers, 2020, 20 (18), pp.10511-10520. ⟨10.1109/JSEN.2020.2995055⟩
IEEE Sensors Journal, 2020, 20 (18), pp.10511-10520. ⟨10.1109/JSEN.2020.2995055⟩
IEEE Sensors Journal, Institute of Electrical and Electronics Engineers, 2020, 20 (18), pp.10511-10520. ⟨10.1109/JSEN.2020.2995055⟩
MEMS (Micro Electro Mechanical System) switches were assessed and compared to PIN diode in fulfilling the task of active decoupling of Receiver Endoluminal Coils (RECs). Three prototype RECs with the PIN diode in parallel ( ${p}$ PIN), MEMS in parall
Autor:
Pauline Hinault, Isabelle Gardin, Pierrick Gouel, Pierre Decazes, Sebastien Thureau, Ovidiu Veresezan, Henri Souchay, Pierre Vera, David Gensanne
Publikováno v:
Journal of applied clinical medical physics. 23(7)
The purpose of this study was to evaluate the positioning uncertainties of two PET/CT-MR imaging setups, C1 and C2. Because the PET/CT data were acquired on the same hybrid device with automatic image registration, experiments were conducted using CT
Publikováno v:
Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering
Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering, Wiley, 2021, 2021, pp.1-15. ⟨10.1155/2021/6614696⟩
Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering, 2021, 2021, pp.1-15. ⟨10.1155/2021/6614696⟩
Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering, Wiley, 2021, 2021, pp.1-15. ⟨10.1155/2021/6614696⟩
Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering, 2021, 2021, pp.1-15. ⟨10.1155/2021/6614696⟩
With the objective of improving MR endoluminal imaging of the colonic wall, electromagnetic simulations of different configurations of single-layer and double-layer, and double-turn endoluminal coil geometries were run. Indeed, during colon navigatio
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::e5d55a853e194b09544fc6fe94d2ee83
https://hal.archives-ouvertes.fr/hal-03340041
https://hal.archives-ouvertes.fr/hal-03340041
Publikováno v:
Medical Physics. 34:547-555
The study purpose was to determine the impact of anti-scatter grid removal on patient dose, in full field digital mammography. Dose saving, phantom based, was evaluated with the constraint that images acquired with and without grid would provide the
Publikováno v:
Radiation protection dosimetry. 165(1-4)
X-ray field to image receptor active area alignment is usually tested in mammographic QC. In digital breast tomosynthesis (dBT), the source moves during the acquisition, generating a displacement of the X-ray beam edges relative to the detector, in o
Publikováno v:
SPIE Proceedings.
The MTF (modulation transfer function) of digital radiography systems can be enhanced in the spatial frequency domain due to their high signal to noise ratio. A Wiener filter, which requires prior estimation of the noise and signal power spectrum of
Autor:
Henri Souchay, Remy Klausz
Publikováno v:
SPIE Proceedings.
In limited angular aperture tomosynthesis systems, the addition of new degrees of freedom for data acquisition, such as angular aperture and sampling, requires specific optimizations. Typical optimization criteria include MTF, SNR, and NEQ. However,
Autor:
Gisella, Gennaro, Luc, Katz, Henri, Souchay, Remy, Klausz, Claudio, Alberelli, Cosimo, di Maggio
Publikováno v:
Medical physics. 34(2)
The study purpose was to determine the impact of anti-scatter grid removal on patient dose, in full field digital mammography. Dose saving, phantom based, was evaluated with the constraint that images acquired with and without grid would provide the
Publikováno v:
Medical Imaging 2007: Image Perception, Observer Performance, and Technology Assessment.
To accurately detect radiological signs of cancer, mammography requires the best possible image quality for a target patient dose. The application of automatic optimization of parameters (AOP) to digital systems has been improved recently. The metric
Publikováno v:
SPIE Proceedings.
Burgess showed that lesion detectability does have a non-trivial behavior with textured mammographic backgrounds: the threshold detectability occurs when the log contrast is linearly related to the log size with positive slope. Grosjean et al. propos