Zobrazeno 1 - 7
of 7
pro vyhledávání: '"Hee Yun Shin"'
Publikováno v:
Journal of Nuclear Materials. 417:63-66
In order for a Korean Helium Cooled Molten Lithium (HCML) Test Blanket Module (TBM) to be tested in the International Thermonuclear Experimental Reactor (ITER), fabrication method for the TBM FW such as Hot Isostatic Pressing (HIP, 1050 °C, 100 MPa,
Publikováno v:
Fusion Engineering and Design. 86:412-416
As a party of the ITER, especially as a procurement party of the ITER blanket, we have designed the first wall qualification mockup (FWQM) and fabricated four FWQMs. Two of them have been tested up to 12,690/12,020 cycles at a heat flux higher than 0
Publikováno v:
Journal of the Korean Vacuum Society. 18:318-330
A high heat flux test facility using a graphite heating panel was constructed and is presently in operation at Korea Atomic Energy Research Institute, which is called KoHLT-1. Its major purpose is to carry out a thermal cycle test to verify the integ
Publikováno v:
Journal of the Korean Welding and Joining Society. 26:66-72
Because of high intensity and easy controllability of the heat source, high frequency induction heating has been concerned and studied for the steel forming process in the ship building industry. However, the heating and forming characteristics have
Publikováno v:
Journal of the Korean Welding and Joining Society. 25:24-29
Finite element analysis for induction heating process including magnetic and thermal situations is presented. Because magnetic and thermal material properties vary with the temperature, material properties depending on temperature are considered. As
Publikováno v:
2009 23rd IEEE/NPSS Symposium on Fusion Engineering.
We established a heat load test facility using a graphite heating panel in 2008 in order to verify the integrity of a HIP bonded first wall. The facility is called KoHLT-1 and is currently in operation to test the Be mockups. The KoHLT-1 consists of
Publikováno v:
2009 23rd IEEE/NPSS Symposium on Fusion Engineering; 2009, p1-4, 4p