Autor:
Luc Beaulieu, Gustavo Kertzscher, J.G. Johansen, Joakim Overgaard, Haydee M. Linares Rosales, Kari Tanderup, Dominique Piché-Meunier, Erik Jørgensen, Sam Beddar, Daline Tho
Publikováno v:
Jørgensen, E B, Johansen, J G, Overgaard, J, Piché-Meunier, D, Tho, D, Rosales, H M L, Tanderup, K, Beaulieu, L, Kertzscher, G & Beddar, S 2021, ' A high-Z inorganic scintillator–based detector for time-resolved in vivo dosimetry during brachytherapy ', Medical Physics, vol. 48, no. 11, pp. 7382-7398 . https://doi.org/10.1002/mp.15257
Purpose: High-dose rate (HDR) and pulsed-dose rate (PDR) brachytherapy would benefit from an independent treatment verification system to monitor treatment delivery and to detect errors in real time. This paper characterizes and provides an uncertain
Autor:
J. Dupere, Luc Beaulieu, Gabriel Famulari, Haydee M. Linares Rosales, David C. Medich, Shirin A. Enger
Publikováno v:
Medical Physics. 47:4563-4573
PURPOSE A prototype 169 Yb source was developed in combination with a dynamic rotating platinum shield system (AIM-Brachy) to deliver intensity modulated brachytherapy (IMBT). The purpose of this study was to evaluate the dosimetric characteristics o
Publikováno v:
Medical Physics. 47:4477-4490
PURPOSE This study aims to present the performance of a multipoint plastic scintillation detector (mPSD) as a tool for real-time dose measurements (covering three orders of magnitude in dose rate), source-position triangulation, and dwell time assess
Publikováno v:
Nucleus, Vol 0, Iss 57 (2015)
The evaluation of the solid state detectors response based on a Monte Carlo model of an Elekta Precise lineal accelerator, was done in this work for the beam energies of 6 y 15 MV. Simulations were performed using the EGSnrc code. Employing the optim
Externí odkaz:
https://doaj.org/article/c3beba4713d3425da53883b90016ca63
Publikováno v:
Nucleus, Vol 0, Iss 57 (2015)
Simulation of a linear accelerator (linac) head requires determining the parameters that characterize the primary electron beam striking on the target which is a step that plays a vital role in the accuracy of Monte Carlo calculations. In this work,
Externí odkaz:
https://doaj.org/article/02101449199f40c4835a3d608de121aa
Publikováno v:
Nucleus, Vol 0, Iss 57 (2015)
The analysis of some parameters of interest in radiotherapy Medical Physics based on an experimentally validated Monte Carlo model of an Elekta Precise lineal accelerator was performed for 6 and 15 MV photon beams. The simulations were performed usin
Externí odkaz:
https://doaj.org/article/b6d87b17f6724ea8bd273f1bf1791d85
Autor:
Louis Archambault, Patricia Duguay-Drouin, Luc Beaulieu, Haydee M. Linares Rosales, Sam Beddar
Publikováno v:
Medical Physics. 46:2412-2421
PURPOSE This study is devoted to optimizing and characterizing the response of a multipoint plastic scintillator detector (mPSD) for application to in vivo dosimetry in high dose rate (HDR) brachytherapy. METHODS An exhaustive analysis was carried ou
Autor:
Gabriel, Famulari, Haydee M, Linares Rosales, Justine, Dupere, David C, Medich, Luc, Beaulieu, Shirin A, Enger
Publikováno v:
Medical physicsReferences. 47(9)
A prototypeThe TG-43U1 dosimetric parameters were calculated for the source model using RapidBrachyMCTPS. Real-time dose rate measurements were performed in a water tank for both the bare/shielded source using a custom remote afterloader. For each dw
Autor:
Luc Beaulieu, Daline Tho, André-Guy Martin, Nathalie Dufour, Martine Lefebvre, Audrey Cantin, Sylviane Aubin, Haydee M. Linares Rosales
Publikováno v:
Brachytherapy. 20:S22-S23
Publikováno v:
Medical physicsREFERENCES. 47(9)
This study aims to present the performance of a multipoint plastic scintillation detector (mPSD) as a tool for real-time dose measurements (covering three orders of magnitude in dose rate), source-position triangulation, and dwell time assessment in