Zobrazeno 1 - 9
of 9
pro vyhledávání: '"Harry W. Seipp"'
Publikováno v:
Computers and Biomedical Research. 10:35-44
Computer-assisted analysis of phonocardiograms from 20 Starr-Edwards (SE)-1000 series prosthetic aortic valve patients is described. Six patients had a normal valve (implanted
Publikováno v:
The Journal of Thoracic and Cardiovascular Surgery. 83:659-669
Myocardial infarction following coronary occlusion limits the effectiveness of emergency coronary artery bypass operations. We designed and evaluated a transvenously introduced balloon-tipped catheter and an electrocardiogram-activated pumping system
Autor:
Andrew G. Morrow, P.L. Frommer, Joseph E. Pierce, Harry W. Seipp, Sidney Levitsky, V. Parsonnett, Charles L. McIntosh
Publikováno v:
The Journal of Thoracic and Cardiovascular Surgery. 60:836-841
Publikováno v:
Circulation research. 11
The pulmonary artery-wedge and left atrial pressures were recorded simultaneously in 11 patients during a control state, during norepinephrine infusion, as well as during positive and negative intra-alveolar pressures. A good correlation (r = 0.95) f
Autor:
ANDREW G. MORROW, ROBERT K. BRAWLEY, EUGENE BRAUNWALD, Harry W. Seipp, David E. Cobb, Maxine P. Montgomery
Publikováno v:
Circulation. 31
The volume of regurgitant blood flow and its effects on the performance of the left ventricle were assessed at operation in 14 patients with varying degrees of aortic regurgitation. Instantaneous forward and regurgitant flows in the ascending aorta w
Publikováno v:
Circulation. 35(1)
Instantaneous ascending aortic blood flow and left ventricular and central aortic pressure were determined at the time of operation in nine patients with severe aortic regurgitation. In six, the heart rate was controlled and increased by electrical s
Publikováno v:
Journal of applied physiology. 16
The relationships between pH, CO, tension and total CO2 in spinal fluid and arterial blood were explored in 12 normal individuals and 15 patients with various diseases. It was found that, in the normal subjects, the pH in the spinal fluid was constan
Autor:
Eugene Braunwald, Andrew G. Morrow, George E. Pierce, David E. Cobb, Maxine P. Montgomery, Harry W. Seipp
Publikováno v:
Circulation. 29
Pressures in the left ventricle and central aorta were recorded together with instantaneous aortic blood flow at the time of operation in 9 patients. Four patients had IHSS, 4 had valvular or discrete subvalvular aortic stenosis, and 1 was considered
Conference