Zobrazeno 1 - 10
of 46
pro vyhledávání: '"Haoxi Cong"'
Publikováno v:
CSEE Journal of Power and Energy Systems, Vol 10, Iss 3, Pp 1269-1279 (2024)
The aging problem of vegetable oil has severely restricted the popularization and application of vegetable oil transformers. Adding antioxidants is the most recommended solution. At present, there is insufficient research on the micro-mechanism appli
Externí odkaz:
https://doaj.org/article/6643a894633c47adb036e6e31fa439ad
Publikováno v:
High Voltage, Vol 6, Iss 3, Pp 448-459 (2021)
Abstract In recent years, there have been many cases of transformer failures caused by corrosive sulfides. At present, research mainly focuses on the single sulfide dibenzyl disulphide, but few research on multiple sulphur or the oil‐paper hybrid i
Externí odkaz:
https://doaj.org/article/d45d82c5667542829aecaf478bb963a0
Publikováno v:
High Voltage, Vol 6, Iss 2, Pp 193-209 (2021)
Abstract The active sulphur compounds in transformer oil would react with copper wires and produce cuprous sulphides, which then attach themselves to the surface of copper wires and insulating paper, thus reducing the electrical performance of oil–
Externí odkaz:
https://doaj.org/article/ad652ed9422940d89d6ca94222d40364
Publikováno v:
IEEE Access, Vol 7, Pp 4083-4090 (2019)
The problem of sulfur corrosion has seriously affected the safe and stable operation of the power transformers. Currently, adding passivators into the transformer oil is the most effective method to suppress the problem. However, no explicit provisio
Externí odkaz:
https://doaj.org/article/9bacef97e7a94e2fa00423017314d62c
Publikováno v:
IEEE Access, Vol 7, Pp 101147-101159 (2019)
The vegetable oil transformer has excellent fire resistance, environmentally friendly performances and electrical properties, which is the development direction of oil-filled transformer in the future. At present, the fault diagnosis methods are limi
Externí odkaz:
https://doaj.org/article/25254dcf81264017a54fbdd03a5531f5
Publikováno v:
Applied Sciences, Vol 8, Iss 9, p 1577 (2018)
Corrosive sulfides in transformer oil could react with copper wire to produce cuprous sulfide, causing insulation failure. At present, both the quantitative measurement method and distribution of sulfur components in operating oil are not clear yet.
Externí odkaz:
https://doaj.org/article/2d91c027aaad4b59994df4d7f797bdfb
Publikováno v:
Energies, Vol 11, Iss 4, p 828 (2018)
Secondary arc is more severe in the ultra-high voltage (UHV) power grid. However, the mechanism for the generation process of secondary arc at the extinction moment of a short-circuit arc is not yet clear. It is of great theoretical significance and
Externí odkaz:
https://doaj.org/article/6690de6a80c5402881c7b90bd3ea4fd7
Publikováno v:
IEEE Transactions on Dielectrics and Electrical Insulation. 30:634-642
Publikováno v:
IEEE Transactions on Instrumentation and Measurement. 72:1-9
Publikováno v:
IEEE Transactions on Dielectrics and Electrical Insulation. 29:1642-1650