Zobrazeno 1 - 10
of 69
pro vyhledávání: '"Hansjörg Rempp"'
Autor:
Susann-Cathrin Olthof, Daniel Wessling, Moritz T. Winkelmann, Hansjörg Rempp, Konstantin Nikolaou, Rüdiger Hoffmann, Stephan Clasen
Publikováno v:
Insights into Imaging, Vol 13, Iss 1, Pp 1-10 (2022)
Abstract Background Radiofrequency ablation (RFA) is a minimal-invasive, local therapy in patients with circumscribed metastatic disease. Although widely used, long time survival analysis of treated liver metastases is still pending while also analys
Externí odkaz:
https://doaj.org/article/887c3199473c444aadc643de185feca4
Autor:
Susann-Cathrin, Olthof, Daniel, Wessling, Moritz T, Winkelmann, Hansjörg, Rempp, Konstantin, Nikolaou, Rüdiger, Hoffmann, Stephan, Clasen
Publikováno v:
Insights into imaging. 13(1)
Radiofrequency ablation (RFA) is a minimal-invasive, local therapy in patients with circumscribed metastatic disease. Although widely used, long time survival analysis of treated liver metastases is still pending while also analysing the patients' ex
Autor:
Stephan Clasen, Rüdiger Hoffmann, Konstantin Nikolaou, Jakob Weiß, Philippe L. Pereira, David-Emanuel Keßler, Hansjörg Rempp
Publikováno v:
European Radiology. 27:1467-1476
Evaluation of the technical success, patient safety and technical effectiveness of magnetic resonance (MR)-guided microwave ablation of hepatic malignancies. Institutional review board approval and informed patient consent were obtained. Fifteen pati
Autor:
C la Fougère, Hansjörg Rempp, Christina Pfannenberg, Konstantin Nikolaou, Nina F. Schwenzer, Christina Schraml, Holger Schmidt, Cornelia Brendle
Publikováno v:
European Journal of Nuclear Medicine and Molecular Imaging. 43:123-132
The purpose was to investigate the diagnostic performance of different combinations of anatomical and functional imaging techniques in PET/MRI and PET/CT for the evaluation of metastatic colorectal cancer lesions. Image data of 15 colorectal cancer p
Autor:
Gunnar Blumenstock, Hansjörg Rempp, Rüdiger Hoffmann, Stephan Clasen, David-Emanuel Keßler, Konstantin Nikolaou, Jakob Weiß, Frank Eibofner, Philippe L. Pereira
Publikováno v:
European Radiology. 26:771-779
To evaluate and compare artefact configuration and diameters in a magnetic resonance (MR)-compatible prototype microwave (MW) applicator and a standard MR-compatible radiofrequency (RF) applicator for MR-guided tumour ablation.Both applicators were t
Autor:
David-Emanuel Kessler, Hansjörg Rempp, Philippe L. Pereira, Rüdiger Hoffmann, Jakob Weiss, Konstantin Nikolaou, Stephan Clasen
Publikováno v:
Minimally invasive therapyallied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy. 27(1)
To evaluate artifact configuration and diameters of a magnetic resonance (MR) compatible microwave (MW) applicator using near-realtime MR-fluoroscopic sequences for percutaneous tumor ablation procedures.Two MW applicators (14 G and 16 G) were tested
Autor:
Jakob Weiss, Hansjörg Rempp, Stephan Clasen, Philippe L. Pereira, Konstantin Nikolaou, David-Emanuel Kessler, Rüdiger Hoffmann
Publikováno v:
International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group. 33(6)
Evaluation of a newly developed MR-compatible microwave ablation system with focus on ablation performance and comparison with a corresponding standard microwave ablation system.A total of 52 ablations were performed with a non-cooled microwave ablat
Autor:
Ralf-Thorsten Hoffmann, Claus D. Claussen, Hansjörg Rempp, J. Bustamante, C. Pitsaer, M. D. Enderle, M Voigtländer, Stephan Clasen
Publikováno v:
RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren. 186:945-950
Purpose: Energy transfer from radiofrequency (RF) applicator to tissue is both precondition and limiting factor. The purpose of this ex vivo study was to examine the influence of form of energy delivery on ablation result during RF ablation with cryo
Publikováno v:
Der Radiologe. 53:986-992
Bisweilen werden perkutane minimal-invasive Therapien unter bildgebender Kontrolle mit Ultraschall, Computertomographie (CT) und Durchleuchtung durchgefuhrt. Die Magnetresonanztomographie (MRT) wird zunehmend als Bildgebungsmodalitat fur minimal-inva
Autor:
Hansjörg Rempp, Stephan Clasen, Ludwig Erhard, Claus D. Claussen, Rüdiger Hoffmann, Philippe L. Pereira, Gunnar Blumenstock
Publikováno v:
Radiology. 268:89-97
To compare volume, sphericity, and short-axis diameter of the coagulation zone of four commercially available microwave ablation systems with three technical concepts in an ex vivo setting and to formulate mathematical models to predict these quantit