Autor:
Hans Roehrig, Syed F. Hashmi, Louis D. Silverstein, Ronald S. Weinstein, Elizabeth A. Krupinski, Anna R. Graham
Publikováno v:
Journal of Digital Imaging. 25:738-743
The use of color LCDs in medical imaging is growing as more clinical specialties use digital images as a resource in diagnosis and treatment decisions. Telemedicine applications such as telepathology, teledermatology, and teleophthalmology rely heavi
Autor:
Elizabeth A. Krupinski, Hans Roehrig, William J. Dallas, Karl Lang, Louis D. Silverstein, Syed F. Hashmi
Publikováno v:
SID Symposium Digest of Technical Papers. 42:1026-1029
A methodology and associated software modules for calibration, characterization and profiling of color LCDs for color-critical applications such as medical imaging is described. Supporting analyses reveal very high color reproduction accuracy as dete
Autor:
Hans Roehrig, Anna R. Graham, Ronald S. Weinstein, Elizabeth A. Krupinski, Jeffrey P. Johnson, Michelle Yan
Publikováno v:
IEEE Transactions on Medical Imaging. 30:306-314
A major issue in telepathology is the extremely large and growing size of digitized "virtual" slides, which can require several gigabytes of storage and cause significant delays in data transmission for remote image interpretation and interactive vis
Publikováno v:
Academic Radiology. 14:463-467
Rationale and Objectives As liquid crystal displays (LCDs) age, the whitepoint shifts toward a yellow hue, changing the appearance of the displayed images. This study examined whether this shift in whitepoint influences observer performance and visua
Publikováno v:
Journal of Digital Imaging. 18:311-315
Full-field digital mammography (FFDM) systems are currently being used to acquire mammograms in digital format, but digital displays are less than ideal compared to traditional film-screen display. Certain physical properties of softcopy displays [e.
Publikováno v:
Academic Radiology. 12:957-964
Rationale and Objectives Although cathode-ray tube (CRT) displays typically are used for softcopy display of radiographs in the digital reading environment, liquid crystal displays (LCDs) currently are being used as an alternative. LCDs have many des
Publikováno v:
International Congress Series. 1281:92-97
Results of physical as well as psychophysical evaluation of an LCD with respect to its spatial noise are presented. Spatial noise is determined using a high-resolution CCD camera and a method is developed to compensate for it. This compensation algor
Autor:
William J. Dallas, Elizabeth A. Krupinski, Jiahua Fan, Hans Roehrig, Kunal Gandhi, Malur K. Sundareshan
Publikováno v:
Medical Physics. 32:578-587
Recent developments in liquid crystal display(LCD) technology suggest that this technology will replace the cathode ray tube (CRT) as the most popular softcopy display technology in the medical arena. However, LCDs are far from ideal for medical imag
Use of a Human Visual System Model to Predict Observer Performance with CRT vs LCD Display of Images
Autor:
Jiahua Fan, Jeffrey P. Johnson, Hans Roehrig, John S. Nafziger, Elizabeth A. Krupinski, Jeffery Lubin
Publikováno v:
Journal of Digital Imaging. 17:258-263
This Project evaluated a human visual system model (JNDmetrix) based on just noticeable difference (JND) and frequency-channel vision-modeling principles to assess whether a Cathode ray tube (CRT) or a liquid crystal display (LCD) monochrome display
Publikováno v:
CARS
This paper describes a CCD camera, which was developed for in-field evaluation of the image quality of electronic display devices like Cathode Ray Tube displays (CRTs) and Liquid Crystal displays (LCDs). Contrary to traditional CCD cameras used for i