Zobrazeno 1 - 10
of 16
pro vyhledávání: '"Hans F. Ginz"'
Autor:
Hans F Ginz, Andreas Rutherford
Publikováno v:
Anesthesia and Critical Care.
We report the rare case of an adult sepsis patient with very low urea blood values, a high anion gap metabolic acidosis, and high ammonia levels. After exclusion of a primary disturbance of the urea cycle, we found a severe pyroglutamic (also called
Publikováno v:
Muscle & Nerve. 53:913-917
INTRODUCTION In myopathy patients, it is useful to measure skeletal muscle forces. Conventional methods require voluntary muscle activation, which can be unreliable. We evaluated a device for nonvoluntary force assessment. METHODS We tested 8 patient
Background. Our aim was to quantify human involuntary isometric skeletal muscle strength during anaesthesia with propofol, sevoflurane, or spinal anaesthesia using bupivacaine. Methods. Thirty‐three healthy patients undergoing anaesthesia for elect
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::2ae2c79109a0a52d835f2d883fad66c1
http://doc.rero.ch/record/289712/files/aeh080.pdf
http://doc.rero.ch/record/289712/files/aeh080.pdf
Publikováno v:
Journal of Medical Engineering & Technology. 38:227-231
ICU patients typically are given large amounts of fluid and often develop oedema. The purpose of this study was to evaluate whether the oedema would change inter-electrode resistance and, thus, require a different approach to using non-invasive elect
Publikováno v:
Musclenerve. 53(6)
In myopathy patients, it is useful to measure skeletal muscle forces. Conventional methods require voluntary muscle activation, which can be unreliable. We evaluated a device for nonvoluntary force assessment.We tested 8 patients (unknown myopathy n
Next Generation of A Non-Invasive-Stimulated Muscle Force Assessment System to Study the ICU Patient
Publikováno v:
Journal of Medical Devices. 6
Autor:
Soledad Levano, Jan Benthien, Albert Urwyler, Alain Li Wan Po, Thierry Girard, H. Rüffert, Hans F. Ginz
Publikováno v:
Pharmacogenetics and genomics. 19(12)
BACKGROUND: The in-vitro contracture test is the standard test to diagnose malignant hyperthermia (MH) susceptibility. Maximum sensitivity is important for patient safety. For scientific purposes, the reduced specificity of contracture testing is a m
Autor:
Hans F. Ginz, Paul A. Iaizzo, Charles L. Soule, Albert Urwyler, Oliver Bandschapp, Thierry Girard
Publikováno v:
Anesthesiology. 111(3)
Background Anesthetic choice for patients with chloride channel myotonia remains under debate. The authors have, therefore, investigated the in vitro effects of various anesthetic agents on pharmacologically induced chloride channel myotonia. Methods
Publikováno v:
Journal of Medical Devices. 2
Objective: To optimize the assessment of muscle weakness in critically ill patients in the intensive care unit (ICU) by development non-invasive, reproducible assessment devices and application protocols. Methods: For over 5years we evaluated weaknes
Publikováno v:
Swiss Medical Weekly.
QUESTION UNDER STUDY Critically ill patients can develop muscle weakness that prolongs recovery. The aim of this study was to evaluate contractile parameters of the involuntary isometric skeletal muscle forces as measures of muscle weakness in critic