Zobrazeno 1 - 6
of 6
pro vyhledávání: '"Hannes Nierath"'
Autor:
Patricia Fuchs, Juliane Obermeier, Svend Kamysek, Martin Degner, Hannes Nierath, Henning Jürß, Hartmut Ewald, Jens Schwarz, Martin Becker, Jochen K. Schubert
Publikováno v:
BMC Emergency Medicine, Vol 17, Iss 1, Pp 1-8 (2017)
Abstract Background Contemporary resuscitation guidelines for basic life support recommend an immediate onset of cardiac compressions in case of cardiac arrest followed by rescue breaths. Effective ventilation is often omitted due to fear of doing ha
Externí odkaz:
https://doaj.org/article/028e57619b8e4c95934049d91026c7c3
Autor:
Rainer Bader, Wolfram Mittelmeier, Hartmut Ewald, Hannes Nierath, Andrea Boehme, Christian Schulze, Cathérine Ruther, Daniel Kluess
Publikováno v:
Sensors, Vol 13, Iss 1, Pp 1-20 (2012)
Currently, imaging methods are used to diagnose loosening of endoprosthetic implants, but fail to achieve 100% accuracy. In this study, a passive sensor array which is based on the interaction between magnetic oscillators inside the implant and an ex
Externí odkaz:
https://doaj.org/article/95d1e6f018ac4f0a85c83fcb76138e70
Autor:
Jens Schwarz, Svend Kamysek, Patricia Fuchs, Hannes Nierath, Henning Jurs, Juliane Obermeier, Jochen K. Schubert, Martin Becker, Hartmut Ewald, Martin Degner
Publikováno v:
BMC Emergency Medicine
BMC Emergency Medicine, Vol 17, Iss 1, Pp 1-8 (2017)
BMC Emergency Medicine, Vol 17, Iss 1, Pp 1-8 (2017)
Background Contemporary resuscitation guidelines for basic life support recommend an immediate onset of cardiac compressions in case of cardiac arrest followed by rescue breaths. Effective ventilation is often omitted due to fear of doing harm and fe
Autor:
Hannes Nierath, Andrea Boehme, Daniel Kluess, Cathérine Ruther, Rainer Bader, Hartmut Ewald, Wolfram Mittelmeier, Christian Schulze
Publikováno v:
Sensors, Vol 13, Iss 1, Pp 1-20 (2012)
Sensors (Basel, Switzerland)
Sensors; Volume 13; Issue 1; Pages: 1-20
Sensors (Basel, Switzerland)
Sensors; Volume 13; Issue 1; Pages: 1-20
Currently, imaging methods are used to diagnose loosening of endoprosthetic implants, but fail to achieve 100% accuracy. In this study, a passive sensor array which is based on the interaction between magnetic oscillators inside the implant and an ex
Autor:
Rainer Bader, James L. Cunningham, Hartmut Ewald, Cathérine Ruther, Wolfram Mittelmeier, Daniel Kluess, Hannes Nierath
Publikováno v:
Medical engineeringphysics. 35(11)
Precise diagnosis of loosening of endoprosthetic implants plays an important role in timely, adequate treatment. However, today's diagnostic tools, mainly radiological evaluation, do not yield satisfactory results. Therefore, a new approach based on
Autor:
Martin Degner, Martin Becker, Jens Schwarz, Hartmut Ewald, Svend Kamysek, Patricia Fuchs, Juliane Obermeier, Henning Jurs, Jochen K. Schubert, Hannes Nierath
Publikováno v:
Resuscitation. 96:50