Zobrazeno 1 - 9
of 9
pro vyhledávání: '"Hanan Amro"'
Autor:
Daniel L. McShan, Karen Vineberg, Howard M. Sandler, Dale W. Litzenberg, Daniel A. Hamstra, Hanan Amro, Scott W. Hadley
Publikováno v:
International Journal of Radiation Oncology*Biology*Physics. 85:230-236
Purpose To study the impact of daily rotations and translations of the prostate on dosimetric coverage during radiation therapy (RT). Methods and Materials Real-time tracking data for 26 patients were obtained during RT. Intensity modulated radiation
Autor:
Dale W. Litzenberg, Joann I. Prisciandaro, D. A. Roberts, Hanan Amro, E Acosta, Ian Gallagher
Publikováno v:
Journal of Applied Clinical Medical Physics
The purpose of this study was to determine the dosimetric impact of density variations observed in water‐equivalent solid slabs. Measurements were performed using two 30 cm×30 cm water‐equivalent slabs, one being 4 cm think and the other 5 cm th
Publikováno v:
Journal of Nuclear Medicine. 51:654-659
A 3-dimensional (3D) imaging–based patient-specific dosimetry methodology incorporating antitumor biologic effects using biologically effective dose (BED) and equivalent uniform dose (EUD) was developed in this study. The methodology was applied to
Autor:
Hanan Amro, Kenneth F. Koral, Scott J. Wilderman, Peter L. Roberson, Denise Regan, Yuni K. Dewaraja, Anca M. Avram, Mark S. Kaminski, Matthew J. Schipper
Publikováno v:
Journal of nuclear medicine : official publication, Society of Nuclear Medicine. 51(7)
For optimal treatment planning in radionuclide therapy, robust tumor dose–response correlations must be established. Here, fully 3-dimensional (3D) dosimetry was performed coupling SPECT/CT at multiple time points with Monte Carlo–based voxel-by-
Autor:
Daniel L. McShan, Karen Vineberg, Daniel A. Hamstra, Howard M. Sandler, Dale W. Litzenberg, Hanan Amro, Scott W. Hadley
Publikováno v:
Medical Physics. 38:3781-3781
Purpose: To measure the dose decrement to the prostate caused by daily prostate motion and to correlate target coverage with prostate rotations to establish individualized rotational tolerances and PTV margins. Methods: Real—time tracking data for
Publikováno v:
Medical Physics. 37:3190-3190
Purpose: To determine the impact of prostate shape and daily intra‐fraction translations and rotations on CTV coverage for PTV margins of 2, 3 and 5 mm. Materials/Methods: Twenty‐six patients with adenocarcinoma of the prostate were treated using
Publikováno v:
Medical Physics. 36:2627-2627
Purpose: The efficacy of targeted radionuclide therapy depends on the uniformity of radionuclide distribution within the target volume as well as on the radiosensitivity of the tissue. The inclusion of dose non uniformity and biologic effects in the
Publikováno v:
Medical Physics. 35:2818-2818
Purpose: Individualized treatment planning may benefit from equivalent uniform dose (EUD) techniques to help correlate ‘dose’ with objective patient outcome such as time to recurrence or response rate. Our objective is to illustrate methods used
Publikováno v:
Medical Physics. 35:2783-2783
Purpose:Interfacedosimetry measurements in heterogeneous phantoms are subject to additional uncertainties when using solid materials due to the presence of air gaps between the materials and the detector. The use of solid materials also limits the lo