Zobrazeno 1 - 10
of 26
pro vyhledávání: '"Hamza Salih Erden"'
Autor:
Hamza Salih ERDEN, İsmail TÜRKMEN
Publikováno v:
Volume: 37, Issue: 4 1883-1898
Gazi Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi
Gazi Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi
Önceki optimizasyon çalışmaları sistem odası kliması (computer room air handling, CRAH) baypas (BP) yönteminin veri merkezlerindeki enerji tasarruf potansiyelini oda seviyesinde akış ağı modelleme ve soğutma altyapısı seviyesinde termo
Publikováno v:
Sustainable Cities and Society. 96:104628
The recent spike in the demand for high-performance computing (HPC) server systems has created many challenges in data centers (DCs) including thermal management, system reliability sustenance and server failure minimalization. Lately, deep neural ne
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::9e2edc246f422417c2541162d1b5628e
https://doi.org/10.21203/rs.3.rs-1211668/v1
https://doi.org/10.21203/rs.3.rs-1211668/v1
Autor:
Ozan Gozcu, Hamza Salih Erden
Publikováno v:
TURKISH JOURNAL OF ELECTRICAL ENGINEERING & COMPUTER SCIENCES. 27:2197-2212
Mechanical cooling is responsible for a significant fraction of the energy consumption of data centers (DCs). Free cooling systems take advantage of ambient conditions to reduce the need for compressor-based cooling. This study utilizes thermodynamic
Autor:
Hamza Salih Erden
Publikováno v:
Sustainable Energy Technologies and Assessments. 52:102120
Publikováno v:
Energy and Buildings. 267:112164
Publikováno v:
Journal of Electronic Packaging. 142
The share of equipment and power use in smaller data centers (DCs) is comparable with that of more massive counterparts. However, they grabbed less attention in the literature despite being less energy-efficient. This study highlights the challenges
Computer room air handling (CRAH) bypass (BP) method is an application that reduces the total fan power in air-cooled data centers by lowering CRAH fan speed. BP fans supply the complementary fraction of server airflow from warmer room air through lo
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::28e6d7ff6cba68d26d7416d1378e51fe
https://aperta.ulakbim.gov.tr/record/11151
https://aperta.ulakbim.gov.tr/record/11151
Publikováno v:
IEEE Transactions on Components, Packaging and Manufacturing Technology. 7:1981-1989
Aisle containment systems reduce temperature nonuniformities in traditional air-cooled data centers and pave the way for higher cooling air temperature and more efficient operation of the cooling system and wider application of economizers. However,
Publikováno v:
IEEE Transactions on Components, Packaging and Manufacturing Technology. 7:1795-1803
Aisle containment separates hot and cold aisles in air-cooled data centers to prevent hot air recirculation into cold aisle and decrease temperature nonuniformity among the servers. Uniform server inlet temperatures allow the cooling system to operat