Zobrazeno 1 - 10
of 10
pro vyhledávání: '"Hamed Keramati"'
Publikováno v:
PLoS ONE, Vol 18, Iss 12 (2023)
Externí odkaz:
https://doaj.org/article/020d77d2e4264758aeb2b71f8df8c273
Publikováno v:
Biomechanics and Modeling in Mechanobiology. 19:2643-2656
Aortic dissection (AD) is one of the most catastrophic cardiovascular diseases. AD occurs when a layer inside the aorta is disrupted and gives rise to the formation of a true lumen and a false lumen. These lumens can be connected through tears in the
Publikováno v:
International journal for numerical methods in biomedical engineeringREFERENCES. 38(6)
The computational cost of a three-dimensional (3D) fluid-structure interaction (FSI) simulation of a dissected aorta has prevented researchers from investigating the effect of a wide range of the heart rate on the hemodynamic quantities in the diseas
Publikováno v:
MATHMOD 2022 Discussion Contribution Volume.
Autor:
Sangho Kim, Ching Kit Chen, Masakazu Nakao, Frans N. van de Vosse, Lex van Houts, Hwa Liang Leo, Hamed Keramati
Publikováno v:
International Journal for Numerical Methods in Biomedical Engineering, 37(4):e3436. Wiley-Blackwell
Tetralogy of Fallot (TOF) is a congenital heart anomaly that causes a drastic reduction in the oxygen level. In this study, we coupled a lumped-parameter model with a patient-specific three-dimensional (3D) model which included a modified Blalock-Tau
Autor:
Hwa Liang Leo, Ngoc-Duy Dinh, Chia-Hung Chen, Erik Birgersson, Marek Kukumberg, Song Guo, Hamed Keramati, Theodoros Kofidis, Dinh-Tuan Phan, Abdul Jalil Rufaihah, Anh Tuan Nguyen, Nurdiyana Binte Jaafar, Ruby Yun-Ju Huang
Publikováno v:
Lab on a chip. 20(15)
Cardiovascular disease is a chronic disease that leads to impaired cardiac function and requires long-term management to control its progression. Despite the importance of hydrogels for therapeutic applications, a contradiction between the size of a
Autor:
Ashwin Seetharaman, Hamed Keramati, Kollengode Ramanathan, Matthew E Cove, Sangho Kim, Kian Jon Chua, Hwa Liang Leo
Publikováno v:
Physics of Fluids. 33:061908
Veno-arterial extra corporeal membrane oxygenation (VA-ECMO) is a modified heart lung machine used for patients with both heart and lung failure. This results in retrograde supply of oxygenated blood through the femoral artery in which the unsteady p
Publikováno v:
Microsystem Technologies. 23:5717-5725
This paper presents the fabrication and performance characterization of miniature axial fans that are developed using 2D blade profiles. 12 prototypes, with an outer diameter of 5 mm, having different blade angles and blade profiles were fabricated u
Autor:
Hamed Keramati
As miniaturization technologies improve, electronic devices are becoming smaller and, hence, smaller devices are needed for heat removal. Micro fans are very crucial in compact cooling technologies. Among them, axial fans have unique properties that
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::4e2fc3f59c5dba4eba1925418c28087d
https://doi.org/10.32657/10356/41856
https://doi.org/10.32657/10356/41856
Publikováno v:
Journal of Micro/Nanolithography, MEMS, and MOEMS. 10:033014
As miniaturization technologies have improved for the past few decades, electronic devices are becoming smaller and the technology needed to fabricate complex three-dimensional (3D) microstructures becomes important. Photolithography is a relatively