Zobrazeno 1 - 10
of 160
pro vyhledávání: '"Haiyang Mao"'
Publikováno v:
Microsystems & Nanoengineering, Vol 8, Iss 1, Pp 1-11 (2022)
Abstract Traditional humidity sensors for respiration monitoring applications have faced technical challenges, including low sensitivity, long recovery times, high parasitic capacitance and uncalibrated temperature drift. To overcome these problems,
Externí odkaz:
https://doaj.org/article/435e71fa0a184e6caa1ee471e1eebb61
Publikováno v:
Taiyuan Ligong Daxue xuebao, Vol 52, Iss 4, Pp 585-591 (2021)
To meet the needs of low-cost and easy-to-prepare surface enhanced Raman scattering (SERS) substrate in practical application, plasma technology was used to treat poly(methyl methacrylate) (PMMA) to form nanofiber structures on the surface, and combi
Externí odkaz:
https://doaj.org/article/8bf32bf057ff4ee288dda4c6d645c196
Publikováno v:
Micro & Nano Letters, Vol 16, Iss 7, Pp 392-398 (2021)
Abstract Three‐dimensional nanowire arrays based on different biomaterials have emerged as promising platforms for the studies of cell behaviours over the years. Fabrication of nanosurfaces with complex geometries and controllable morphologies is s
Externí odkaz:
https://doaj.org/article/5832165d1eb241008eafc437ff13aa0c
Publikováno v:
Micromachines, Vol 14, Iss 5, p 910 (2023)
In this work, a N/P polySi thermopile-based gas flow device is presented, in which a microheater distributed in a comb-shaped structure is embedded around hot junctions of thermocouples. The unique design of the thermopile and the microheater effecti
Externí odkaz:
https://doaj.org/article/74e77c0db9a649048751fc044a3ad6ba
Autor:
Zeqing Xiang, Meng Shi, Na Zhou, Chenchen Zhang, Xuefeng Ding, Yue Ni, Dapeng Chen, Haiyang Mao
Publikováno v:
Micromachines, Vol 13, Iss 10, p 1717 (2022)
The response time is an important parameter for thermopiles sensors, which reflects the response speed of the device. The accurate measurement of response time is extremely important to evaluate device characteristics for using them in suitable scena
Externí odkaz:
https://doaj.org/article/6a368647f6bb49c38d4fed39aad93001
Publikováno v:
Journal of Innovative Optical Health Sciences, Vol 14, Iss 4, Pp 2141005-1-2141005-10 (2021)
The development of surface-enhanced Raman scattering (SERS) devices for detection of trace pesticides has attracted more and more attention. In this work, a large-area self-assembly approach assisted with reactive ion etching (RIE) is proposed for pr
Externí odkaz:
https://doaj.org/article/a2ce0d304b4146c5b8c5ff0690b72ba0
Publikováno v:
Micromachines, Vol 13, Iss 6, p 945 (2022)
Vacuum equipment has a wide range of applications, and vacuum monitoring in such equipment is necessary in order to meet practical applications. Pirani sensors work by using the effect of air density on the heat conduction of the gas to cause tempera
Externí odkaz:
https://doaj.org/article/7e4a684c9f764f1aa3dbac0d46824caa
Autor:
Hongbo Li, Chenchen Zhang, Gaobo Xu, Xuefeng Ding, Yue Ni, Guidong Chen, Dapeng Chen, Na Zhou, Haiyang Mao
Publikováno v:
Micromachines, Vol 13, Iss 2, p 258 (2022)
In this article, we present the design, fabrication, and characterization of a thermopile infrared sensor array (TISA) pixel. This TISA pixel is composed of a dual-layer p+/n- poly-Si thermopile with a closed membrane and an n-channel metal oxide sem
Externí odkaz:
https://doaj.org/article/34910bb68b604113a68b6091f3118b74
Publikováno v:
Micromachines, Vol 12, Iss 12, p 1554 (2021)
A thermopile detector with their thermocouples distributed in micro-bridges is designed and investigated in this work. The thermopile detector consists of 16 pairs of n-poly-Si/p-poly-Si thermocouples, which are fabricated using a low-cost, high-thro
Externí odkaz:
https://doaj.org/article/4d5a13acccdd42bba7315601d1e8f6eb
Publikováno v:
IEEE Electron Device Letters. 43:1752-1755