Zobrazeno 1 - 10
of 24
pro vyhledávání: '"HONG-LIANG KE"'
Publikováno v:
Sensors, Vol 21, Iss 9, p 2982 (2021)
In order to improve the precision and beam quality of a pump laser for a spin exchange relaxation free inertial measurement device, we applied one scheme to achieve the square wave modulation and power stability control of the pump laser and another
Externí odkaz:
https://doaj.org/article/f1b9e366f48a4e4ead30b6a2e4e3dba7
Autor:
Jian Hao, Hong-Liang Ke, Yang Shiyu, Miao Peixian, Ji Wang, Cui Jingzhong, Yang Wei, Tu Jianhui, Ren-Tao Sun, Li-Li Zhu, Bao Yang
Publikováno v:
Optik. 180:517-525
Temperature dependent relaxation time of 87Rb atoms, namely the longitudinal relaxation lifetime T1 and the transverse relaxation lifetime T2 are studied respectively by using the Franzen method and by measuring the optical rotation of a weak, linear
Publikováno v:
Sensors (Basel, Switzerland)
Sensors, Vol 21, Iss 2982, p 2982 (2021)
Sensors, Vol 21, Iss 2982, p 2982 (2021)
In order to improve the precision and beam quality of a pump laser for a spin exchange relaxation free inertial measurement device, we applied one scheme to achieve the square wave modulation and power stability control of the pump laser and another
Autor:
Yang Shiyu, Cui Jingzhong, Tu Jianhui, Chao-Quan Wang, Hong-Liang Ke, Jian Hao, Chen Dayong, Miao Peixian
Publikováno v:
Optik. 164:510-518
In this paper, the changes in chromaticity of LED lamps given by online test during accelerated aging under thermal stress were studied. Firstly, two online accelerated aging tests of a same type of lamps were conducted, with one test at the temperat
Publikováno v:
Optik. 149:69-80
In order to quickly acquire the lifetime and reliability prediction for LED lighting products, the method of step-down accelerated aging test based on Nelson models is experimentally studied in this paper. Ten Lide lamps and ten Philips lamps are use
Publikováno v:
Frontiers of Information Technology & Electronic Engineering. 18:1197-1204
To acquire a rational minimum cut-off time and the precision of lifetime prediction with respect to cut-off time for the accelerated aging test of LED lamps, fifth-order moving average error estimation is adopted in this paper. Eighteen LED lamps fro
Publikováno v:
Optik. 134:128-134
An optimization method in the design of freeform surface lens based on non-imaging optics to achieve uniform illumination for LED source is proposed. In this design, regular quadratic curve is used as the initial model, and the Scheme programming lan
Publikováno v:
Solid-State Electronics. 121:47-53
The method of non-contact measurement of the junction temperature (Tj) for phosphor-converted white LEDs based on W/B ratio, the ratio of the total radiant energy (W) to the radiant energy of blue emission (B), is verified firstly. It is shown that f
Publikováno v:
IEEE Transactions on Electron Devices. 63:1148-1153
In this paper, the step-down aging test for light-emitting diode (LED) lamps is designed according to the stopping rule of the IESTM-28 standard and experimental data. The step-down aging experiment is under the temperature stresses of 90 °C, 80 °C
Autor:
Chen Jiang, Zhi-Dong Liu, Jian Hao, Yang Wei, Hong-Liang Ke, Miao Peixian, Cui Jingzhong, Bang-Cheng Han, Zhang Jinhai, Tu Jianhui
Publikováno v:
Optik. 223:165510
Optical pumped magnetometer (OPM) aiming at the measurement of Earth’s magnetic field, is firstly optimized by optical simulation, as to maximize the efficient pumping light. Then Mz-magnetometer and Mx-magnetometer are respectively realized in thi