Zobrazeno 1 - 10
of 14
pro vyhledávání: '"H.-S. Tam"'
Publikováno v:
Calcolo. 42:105-113
Linear systems with M-matrices occur in a wide variety of areas including numerical partial differential equations, input-output production and growth models in economics, linear complementarity problems in op- erations research and Markov chains in
Publikováno v:
ChemInform. 22
The microwave spectra of the syn and anti conformers of difluoroacryloyl fluoride have been assigned and analyzed. Ab initio computations place the syn form lower in energy by 132 cal mol −1 , while the experimental data place the value at 170±100
Autor:
Marlin D. Harmony, H. S. Tam
Publikováno v:
The Journal of Physical Chemistry. 95:9267-9272
Publikováno v:
Journal of Molecular Structure. 244:59-68
The microwave spectra of the syn and anti conformers of difluoroacryloyl fluoride have been assigned and analyzed. Ab initio computations place the syn form lower in energy by 132 cal mol −1 , while the experimental data place the value at 170±100
Publikováno v:
Journal of Molecular Structure. 223:217-230
The microwave spectra of the normal and two monosubstituted isotopomers of difluoropropadienone were observed and assigned in the 26.5–40.0 GHz frequency region. For the normal species, the rotational constants were determined to be A = 11 558.126
Autor:
H. S. Tam, James A. Roberts
Publikováno v:
Structural Chemistry. 1:211-216
A method that combines basic calculations for the moments of inertia and a computer iteration technique over experimental data was employed to evaluate the constantAv in an excited vibrational state for a symmetric top molecule. This method has been
Publikováno v:
Journal of applied physiology. 40(5)
Studies of central and peripheral heating of a resting spinal man (T6) were performed under various ambient temperatures (20–34 degrees C). It was found that at a constant core temperature, sweating could not be initiated by sentient skin heating a
Publikováno v:
Archives of physical medicine and rehabilitation. 57(6)
Dynamic sudomotor response to changing ambient temperatures (30 C to 45 C) was measured on eight unacclimatized subjects including five normals, two paraplegics and one anhidrotic patient. Mean sweating rates, computed from five simultaneously observ
Publikováno v:
Journal of applied physiology: respiratory, environmental and exercise physiology. 45(3)
Publikováno v:
Journal of applied physiology. 41(5 Pt. 1)
The rate of evaporation of sweat under a step change of ambient temperature (30–45 degrees C) was compared with the mean sweating rate (MSR)computed from five simultaneous resistance hygrometric measurements. Empirical equations derived for the con