Publikováno v:
ains · Anästhesiologie · Intensivmedizin · Notfallmedizin · Schmerztherapie. 39:610-615
The skill to safely manage the unexpectedly difficult airway is expected from every anaesthetist. The strategies to safely overcome this severe problem have to be adapted to the given equipment and the individual aptitude and skills of the respective
Publikováno v:
Der Anaesthesist. 49:402-411
Fragestellung. Die Klimatisierung der Narkosegase wird in erheblichem Mas vom Frischgasfluss beeinflusst und ist bei Durchfuhrung von Niedrigflussnarkosen besser als bei hohem Flow. Feuchte und Warme der Gase werden daruber hinaus aber auch von den W
Autor:
J. Baum, H.-G. Stanke
Publikováno v:
Der Anaesthesist. 47:S70-S76
Wegen seiner geringen Loslichkeit und der hohen Maximalkonzentration des substanzspezifischen Verdampfers ist Sevofluran fur die Durchfuhrung von Niedrigflusnarkosen besonders geeignet. Ein- und Auswaschphasen konnen kurz gehalten werden, die Differe
Publikováno v:
Der Anaesthesist. 46:287-293
Desfluran und Frischgasflus Desfluran ist wegen seiner guten Steuerbarkeit ein gerade fur die Durchfuhrung von Niedrigflusnarkosen besonders geeignetes Inhalationsanasthetikum. Bereits nach einer nur 10 min dauernden Initialphase mit hohem Frischgasf
Publikováno v:
Anasthesiologie, Intensivmedizin, Notfallmedizin, Schmerztherapie : AINS. 39(10)
The skill to safely manage the unexpectedly difficult airway is expected from every anaesthetist. The strategies to safely overcome this severe problem have to be adapted to the given equipment and the individual aptitude and skills of the respective
Publikováno v:
Anaesthesiologie und Reanimation. 25(3)
The routine use of nitrous oxide as a component of the carrier gas has been unanimously called into question in recent surveys, in fact, its use is now recommended in indicated cases only. Whereas a lot of contraindications are listed in the surveys,
Publikováno v:
Der Anaesthesist. 49(5)
During general anaesthesia gas climate significantly is improved by performance of low flow techniques. Gas climatisation, however, markedly also will be influenced by the temperature loss at, and corresponding water condensation within the hoses, fa
Autor:
J, Baum, H G, Stanke
Publikováno v:
Der Anaesthesist. 47
Due to its low solubility and the high maximum concentration delivered by the vaporizer sevoflurane is especially suitable for the performance of low flow anaesthetic techniques. High flow phases for wash-in or wash-out of anaesthetic gases can be ke
Publikováno v:
Der Anaesthesist. 46(4)
Due to its low solubility and negligible metabolism, desflurane is assumed to be especially suitable for application by low-flow anaesthetic techniques. The aim of this clinical investigation was the development of a standardised dosing scheme for lo