Zobrazeno 1 - 10
of 23
pro vyhledávání: '"H.-B. Neumann"'
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 372:551-555
The Si matrix of two SiTaSi2 in situ composites grown in the 111 direction have been characterized by means of triple axis diffractometry using synchrotron radiation with photon energies of 120 and 160 keV. The Si matrix is compressed in the growt
Investigation of structural phase transitions in perovskites using high energy synchrotron radiation
Publikováno v:
Technical University of Denmark Orbit
Superstructure and temperature dependence of the critical scattering and the spontaneous strain in SrTiO3 and YBa2Cu3O6+x have been studied using a new 3-crystal diffractometer of high-momentum space resolution for synchrotron radiation with energies
Publikováno v:
Physical Review B. 52:3981-3984
High-q-resolution diffraction experiments performed with 100 keV synchrotron radiation on the identical ${\mathrm{SrTiO}}_{3}$ crystal used in neutron and x-ray-scattering experiments before, unambiguously show that the bulk critical scattering above
Publikováno v:
Technical University of Denmark Orbit
The use of hard X-rays (60–300 keV) for diffraction studies of disordered materials has several advantages: higher resolution in direct space, smaller correction terms, removal of truncation effects, the possibility for operating in extreme environ
Publikováno v:
Journal of Applied Crystallography. 27:1030-1038
The k-space resolution function of a triple-crystal diffractometer is calculated for an arrangement of three perfect silicon single crystals Bragg diffracting in nondispersive Laue geometry. A comparison is made with the results of measurements using
Publikováno v:
Journal of Applied Physics. 73:3680-3684
A three‐crystal diffractometer for synchrotron radiation with energies of 100 keV and higher has been used in a nondispersive setting to map out the distribution of Bragg scattered intensity in the scattering plane with very high resolution. By usi
Publikováno v:
Physica B: Condensed Matter. :982-984
The flat-cone instrument at the BER-II reactor in Berlin is well suited for systematic measurements of elastic and inelastic scattering events in large and continuous areas of Q-space. With this instrument the soft phonon branch, connected with the s
Autor:
T. Brückel, U. Rütt, H.-B. Neumann, M. Lippert, M. von Zirnmermann, J.R. Schneider, T. Schmidt, Henning Friis Poulsen, R. Bouchard
Publikováno v:
Journal de Physique IV Proceedings
Journal de Physique IV Proceedings, EDP Sciences, 1994, 04 (C9), pp.C9-415-C9-421. ⟨10.1051/jp4:1994969⟩
Technical University of Denmark Orbit
Journal de Physique IV Proceedings, EDP Sciences, 1994, 04 (C9), pp.C9-415-C9-421. ⟨10.1051/jp4:1994969⟩
Technical University of Denmark Orbit
The absorption of 150 keV synchrotron radiation in matter is weak and, as normally done with neutrons, bulk properties are studied in large samples. However, the k-space resolution obtained with a Triple Crystal Diffractometer (TCD) for high energy s
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::af4023b7f344a42d9b0fd942bb0517ee
https://hal.archives-ouvertes.fr/jpa-00253532
https://hal.archives-ouvertes.fr/jpa-00253532
Autor:
M. Lippert, J. R. Schneider, Th. Köhler, Th. Brückel, H.-B. Neumann, Tobias Sebastian Schmidt, R. Bouchard, Henning Friis Poulsen, Uta Rütt, M. von Zimmermann
Publikováno v:
Review of Scientific Instruments. 66:1614-1614
Diffraction of high‐energy synchrotron radiation at energies above 100 keV combines advantages of conventional x‐ray diffraction and neutron diffraction. For hard x rays absorption in matter is weak with typical mean free paths of several millime
Autor:
Tobias Sebastian Schmidt, R. Bouchard, Jörg Neuefeind, Thomas Lippmann, U. Rütt, D. Hupfeld, M. von Zimmermann, Henning Friis Poulsen, H.-B. Neumann, J. R. Schneider, J. Süssenbach
Publikováno v:
Technical University of Denmark Orbit
The triple-crystal diffractometer installed at HASYLAB beamline BW5 with a high-field wiggler of critical energy 27 keV for DORIS III, operated at 4.5 GeV electron energy, is described. Samples can be mounted in large cryostats or furnaces normally u
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::aef68f938938ea744867d95b88e86d12
https://orbit.dtu.dk/en/publications/1117d85b-fc31-4fb5-a4ac-591e0d13c382
https://orbit.dtu.dk/en/publications/1117d85b-fc31-4fb5-a4ac-591e0d13c382