Autor:
Krzysztof Walczak, Piotr Przybyłek, Hubert Morańda, Wojciech Sikorski, H. Moscicka-Grzesiak, Mateusz Cybulski
Publikováno v:
IEEE Access, Vol 9, Pp 150322-150329 (2021)
The article concerns a method of drying cellulose insulation of distribution transformers with the use of synthetic ester. This method uses the high solubility of water in the ester compared to other dielectric liquids. The method is based on the str
Publikováno v:
IEEE Transactions on Dielectrics and Electrical Insulation. 27:1538-1545
This article deals with the application of synthetic ester for drying cellulose insulation of distribution transformers. The most important advantages and disadvantages of the commonly used methods of drying transformer insulation on site are discuss
Publikováno v:
Energies, Vol 13, Iss 3467, p 3467 (2020)
Energies
Volume 13
Issue 13
Energies
Volume 13
Issue 13
This paper presents the results of laboratory tests of cellulose insulation drying with the use of synthetic ester. The effectiveness of the drying process was investigated depending on the initial moisture of cellulose samples (2%, 3%, and 4%), este
Publikováno v:
Energies, Vol 13, Iss 3, p 647 (2020)
Energies
Volume 13
Issue 3
Energies
Volume 13
Issue 3
The article presents the results of comparative investigations of partial discharges in two insulation systems
aramid-enhanced cellulose paper-mineral oil, and pure cellulose paper-mineral oil. Partial discharges were investigated in a diagonal
aramid-enhanced cellulose paper-mineral oil, and pure cellulose paper-mineral oil. Partial discharges were investigated in a diagonal
Publikováno v:
Energies, Vol 12, Iss 20, p 3874 (2019)
Energies
Volume 12
Issue 20
Energies
Volume 12
Issue 20
A high level of insulation moisture in a transformer increases the breakdown probability and forces a reduction of its load. Therefore, there is a need to dry the transformer insulation. For technical reasons, there are some restrictions on the use o
Publikováno v:
IEEE Transactions on Dielectrics and Electrical Insulation. 22:3405-3412
This paper refers to the bubble effect in transformer bushings. The bubble effect consists in releasing water from moistened cellulose insulation after exceeding a critical temperature. The most dangerous result is a pressure increase that leads to a
Autor:
H. Moscicka-Grzesiak, K. Feser, Krzysztof Walczak, Piotr Przybyłek, Zbigniew Nadolny, Hubert Morańda, Jarosław Gielniak, A. Graczkowski, Stanislaw Gubanski
Publikováno v:
IEEE Transactions on Dielectrics and Electrical Insulation. 20:982-987
The article presents the results of extensive investigations aimed at determining the moisture content in a large population of power transformers (161 units). The project was carried out during the period of 2003-2011 in Poland, Germany, and Sweden.
Publikováno v:
IEEE Transactions on Dielectrics and Electrical Insulation. 19:1879-1883
This paper elucidates the question whether bubble effect can possibly take place in the insulation of OIP (Oil Impregnated Paper) type of bushings. The investigations were performed on a bushing insulation model and indicated to a possibility that th
Publikováno v:
IEEE Transactions on Dielectrics and Electrical Insulation. 18:1647-1650
The purpose of this work is to evaluate the influence of the cellulose polymerization degree (DP) on the dielectric response. The research objects were new and aged pressboard samples of the polymerization degree 1435 and 406, respectively. The autho
Publikováno v:
IEEE Transactions on Dielectrics and Electrical Insulation. 17:913-919
The main reason of the research was to show the very important role of the dielectric losses in the insulation, during the initiation of water release from paper insulation, which is known as the bubble effect. The authors' thesis is that the dielect