Zobrazeno 1 - 10
of 25
pro vyhledávání: '"H. Menown"'
Publikováno v:
Twentieth Conference Record on Power Modulator Symposium.
A complete thyratron crowbar protection system contained in an oil filled tank is described. This unit can protect klystrons operating at 160KV d.c. and has a dynamic range from 25KV upwards. The crowbar tube developed for the system was CX2098B, a 4
Publikováno v:
Twenty-First International Power Modulator Symposium, Conference.
Publikováno v:
IEEE Conference Record of the 1988 Eighteenth Power Modulator Symposium.
The development of a compact, hollow-anode, high-voltage thyratron, the CX2025, is described. The CX2025 achieves operation at high voltage (60 kV) and high repetition rate (4500 p.p.s.) simultaneously with a high rate of rise of current (70 kA/ mu s
Publikováno v:
IEEE Conference Record of the 1988 Eighteenth Power Modulator Symposium.
A cheater circuit technique for thyratron evaluation is examined in detail. The design, construction and operation of a pilot circuit based on the technique is described. A CX1825 thyratron is operated in the circuit, where the current pulse is 1000
Publikováno v:
Nineteenth IEEE Symposium on Power Modulators.
The authors present results of experiments carried out to ascertain the maximum current carrying capabilities of single gap hydrogen thyratrons of types CX1573 C and CX1574 C. The 3 in diameter CX1573 C has switched 65 kA for 10/sup 5/ shots and the
Autor:
C.A. Pirrie, H. Menown
Publikováno v:
Conference Record of the 2000 Twenty-fourth International Power Modulator Symposium.
The evolution of the hydrogen thyratron from its early beginnings to the present day is presented from the perspective of one manufacturer. Radar requirements drove the development of the hydrogen thyratron as a repetitive, high power line-type modul
Autor:
H. Menown, C. A. Pirrie
Publikováno v:
Gas Discharge Closing Switches ISBN: 9781489921321
Hydrogen thyratrons were developed in the USA during World War II for driving microwave tubes in radar transmitters. In the post war period continuing development produced both glass and ceramic envelope devices. In the UK the development of thyratro
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::c84b42a1e6020d49940352ad5de701b6
https://doi.org/10.1007/978-1-4899-2130-7_15
https://doi.org/10.1007/978-1-4899-2130-7_15
Publikováno v:
IEEE Transactions on Electron Devices. 26:1456-1461
The doubt-ended multigap ceramic thyratron is a versatile switch for crowbar applications. It will provide protection over a very wide range of HT voltages and will operate within a submicrosecond time delay. Since the tube operates in a normal nonde
Publikováno v:
IEEE Transactions on Nuclear Science. 14:260-265
A compact oil immersed modulator is described suitable for driving a 30MW output klystron and using two 70KV 2,500 Amp hydrogen thyratrons as switches. The design is a development of an earlier modulator using a 70KV triggered spark gap. This earlier
Conference
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.