Zobrazeno 1 - 10
of 46
pro vyhledávání: '"H. Keijzer"'
Autor:
Mihai Strachinaru, Jason Voorneveld, Lana B. H. Keijzer, Daniel J. Bowen, Ferit O. Mutluer, Folkert ten Cate, Nico de Jong, Hendrik J. Vos, Johan G. Bosch, Annemien E. van den Bosch
Publikováno v:
Cardiovascular Ultrasound, Vol 20, Iss 1, Pp 1-15 (2022)
Abstract Background Echo-Particle Image Velocimetry (echoPIV) tracks speckle patterns from ultrasound contrast agent(UCA), being less angle-sensitive than colour Doppler. High frame rate (HFR) echoPIV enables tracking of high velocity flow in the lef
Externí odkaz:
https://doaj.org/article/feb6b0a212b8446196aa8cdbed77b8b7
Autor:
Mihai Strachinaru, Johan G. Bosch, Ferit Onur Mutluer, Annemien E. van den Bosch, Daniel J. Bowen, Antonius F.W. van der Steen, Hendrik Vos, Folkert J. ten Cate, Lana B. H. Keijzer, Nico de Jong, Jason Voorneveld
Publikováno v:
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 68(7):9378576, 2432-2443. Institute of Electrical and Electronics Engineers Inc.
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 68(7)
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 68(7)
High-frame-rate (HFR) echo-particle image velocimetry (echoPIV) is a promising tool for measuring intracardiac blood flow dynamics. In this study, we investigate the optimal ultrasound contrast agent (UCA: SonoVue) infusion rate and acoustic output t
Autor:
Annette Caenen, Lana B. H. Keijzer, Hendrik J. Vos, A. Sabbadini, Martin D. Verweij, P.L.M.J. van Neer, N. de Jong
Publikováno v:
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA
The Journal of the Acoustical Society of America, 150(1)
Journal of the Acoustical Society of America, 150(1), 428-440. Acoustical Society of America
The Journal of the Acoustical Society of America, 150(1)
Journal of the Acoustical Society of America, 150(1), 428-440. Acoustical Society of America
Shear wave elastography (SWE) has the potential to determine cardiac tissue stiffness from non-invasive shear wave speed measurements, important, e.g., for predicting heart failure. Previous studies showed that waves traveling in the interventricular
Autor:
M. Amoni, Annette Caenen, R Vos, Jürgen Duchenne, Lana B. H. Keijzer, M Orlowska, Jan D'hooge, J-U Voigt, S Bezy
Publikováno v:
European Heart Journal. 42
Background Several cardiovascular disorders are accompanied by a stiffening of the myocardium and may result in diastolic heart failure. The non-invasive assessment of myocardial stiffness could therefore improve the understanding of the pathophysiol
Autor:
Antonius F.W. van der Steen, Hendrik J. Vos, Rahi Alipour Symakani, Yannick J.H.J. Taverne, Beatrijs Bartelds, Mihai Strachinaru, Annette Caenen, Daphne Merkus, Lana B. H. Keijzer, Luxi Wei
Publikováno v:
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::1fa33ae0b170f22ad9db8b9afc877180
https://biblio.ugent.be/publication/8734391
https://biblio.ugent.be/publication/8734391
Autor:
Annette Caenen, S Bezy, S. Ingelaere, A Puvrez, J D\\'hooge, Keir McCutcheon, M. Amoni, Marta Cvijic, Lana B. H. Keijzer, J-U Voigt, M Orlowska, Hendrik J. Vos, Jürgen Duchenne
Publikováno v:
European Heart Journal - Cardiovascular Imaging. 22
Funding Acknowledgements Type of funding sources: Public grant(s) – National budget only. Main funding source(s): Research Foundation - Flanders (FWO) Background Shear wave elastography (SWE) is a promising tool for the non-invasive assessment of m
Autor:
N. de Jong, Patrick Segers, S Bezy, J-U Voigt, Johannes G. Bosch, Jürgen Duchenne, A.F.W. van der Steen, M Orlowska, J D\\'hooge, Hendrik J. Vos, Lana B. H. Keijzer, Annette Caenen
Publikováno v:
European Heart Journal - Cardiovascular Imaging. 22
Funding Acknowledgements Type of funding sources: Private grant(s) and/or Sponsorship. Main funding source(s): Research Foundation Flanders (FWO): grant 1211620N TTW – Dutch Heart Foundation partnership program "Earlier recognition of cardiovascula
Autor:
Jan D'hooge, J-U Voigt, Annette Caenen, Marta Cvijic, M Orlowska, S Bezy, Jürgen Duchenne, Lana B. H. Keijzer, L Wouters
Publikováno v:
European Heart Journal. 41
Background Shear wave imaging (SWI) is a novel ultrasound technique based on the detection of transverse waves traveling through the myocardium using high frame rate echocardiography. These waves can be naturally induced e.g. by mitral valve closure
Autor:
Annette Caenen, Nico de Jong, Mihai Strachinaru, Daniel J. Bowen, Martin D. Verweij, Johan G. Bosch, Lana B. H. Keijzer, Hendrik J. Vos, Antonius F. W. der van Steen
Publikováno v:
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control, 67(8), 1590-1602. Institute of Electrical and Electronics Engineers Inc.
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control, 67(8), 1590-1602. Institute of Electrical and Electronics Engineers Inc.
Shear wave speed measurements can potentially be used to noninvasively measure myocardial stiffness to assess the myocardial function. Several studies showed the feasibility of tracking natural mechanical waves induced by aortic valve closure in the
Autor:
Lana B. H. Keijzer, Johannes G. Bosch, Marcel L. Geleijnse, Mihai Strachinaru, Daniel J. Bowen, A.F.W. van der Steen, N. de Jong
Publikováno v:
European Heart Journal - Cardiovascular Imaging. 21
Background Shear waves (SW) are induced in the myocardium by the closure of the valves. Recent studies show variations in their propagation velocity with age, gender or pathology. However, these valve-induced waves occur during relaxation and contrac