Zobrazeno 1 - 10
of 46
pro vyhledávání: '"H. J. Zabel"'
Publikováno v:
CARS
Commercial high-field magnetic resonance (MR) scanners are generally not equipped with measurement software and hardware to perform interventional studies with active devices that contain small radiofrequency (rf) coils for localisation. In this stud
Unusual burns of the lower extremities caused by a closed conducting loop in a patient at MR imaging
Publikováno v:
Radiology. 200:572-575
An extremely rare occurrence of third-degree burns was induced in the medial calves of a male patient with unusual anatomy (after resection and radiation therapy of a liposarcoma) during conventional magnetic resonance (MR) imaging on a clinical 1.5-
Autor:
Peter Peschke, G. van Kaick, H. J. Zabel, Walter J. Lorenz, Eric W. Hahn, A. Lorenz, M. Pfeiler, Jürgen Debus, H. Ifflaender
Publikováno v:
Journal of Urology. 146:1143-1146
We are interested in the interaction of pulsed high energy shock waves (PHEUS) on soft tissues treated in situ to evaluate its potential for therapeutic use. The experimental apparatus built by us was adapted from a lithotripter designed for clinical
Publikováno v:
Zeitschrift für Medizinische Physik. 1:169-172
Zusammenfassung In 31 P- 1 H-Doppelresonanz-Experimenten an einem 1,5-Tesla Ganzkorper-MR-System wurden betrachtliche 31 P-MR-Signalintensitatszunahmen von in vivo 31 P-Resonanzen beobachtet (bis ca. 70 % fur die Phosphokreatin-Resonanz in Spektren v
Publikováno v:
Magnetic Resonance in Medicine. 15:165-172
In 31P- {1H} MR experiments of humans in a 1.5-T whole-body system, signal intensity enhancements of 1P resonances of up to 68 ± 4% (for phosphocreatine of the calf muscle) have been observed upon irradiation at proton frequency. This observation is
Publikováno v:
Zeitschrift für Medizinische Physik. 1:16-18
Kurzfassung Mit Hilfe de MR-Bildgebung lassen sich Diffusionsvorgange im Korpergewebe eifassen. Da jedoch im lebenden Organismus das Gewebe und die Korperflussigkeiten in Bewegung sind, konnen die reinen Diffusionskoeffizienten nicht bestimmt werden.
Publikováno v:
Journal of magnetic resonance (San Diego, Calif. : 1997). 133(1)
The anticancer drug carboplatin has been monitored in rats during treatment by means of in vivo 195Pt NMR spectroscopy at 2.0 T. The purpose of the study was to assess local disposition kinetics in intact tissue following subcutaneous injection of a
Publikováno v:
Magnetic resonance imaging. 11(8)
A 19F MR chemical shift imaging (CSI) technique is presented which enables selective imaging of the antineoplastic drug 5-fluorouracil (5-FU) and its major catabolite α-fluoro-β-alanine (FBAL). The CSI sequence employs a chemical shift selective (C
Autor:
H. Iffländer, Eric W. Hahn, A. Lorenz, M. Pfeiler, H. J. Zabel, Peter Peschke, G. Van Kaick, Walter J. Lorenz, Jürgen Debus
Publikováno v:
Ultraschalldiagnostik ’90 ISBN: 9783642934896
Die Zertrummerung von Konkrementen im Korperinneren mit extrakorporal erzeugten Ultraschallstoswellen (ESWL) ist mittlerweile ein klinisch etabliertes Verfahren. Unser Interesse gilt zum einen den Grundlagen der Wechselwirkung derartiger gepulster ho
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::1a162d429bc32836d3ea9782e1b3983d
https://doi.org/10.1007/978-3-642-93488-9_6
https://doi.org/10.1007/978-3-642-93488-9_6
Publikováno v:
Tissue Characterization in MR Imaging ISBN: 9783642749957
T2 values are usually calculated from magnetic resonance (MR) measurements with homogeneous RF transmitting and receiving fields using body or head resonators for the examination of humans. However, these resonators have a reduced signal-to-noise rat
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::e907dfdbb2c11809eedc3d070204987d
https://doi.org/10.1007/978-3-642-74993-3_4
https://doi.org/10.1007/978-3-642-74993-3_4