Zobrazeno 1 - 10
of 67
pro vyhledávání: '"H. J. Selbach"'
Autor:
Andreas Schönfeld, Theodor W. Kaulich, Günther Hartmann, Michael Niekamp, Golam Abu Zakaria, N Chofor, Frank-André Siebert, U. Quast, Michael Andrássy, Renate Walter, H. J. Selbach, Frank W. Hensley, Dietrich Harder, Edmund Schüle, Björn Poppe, Michael Kollefrath, Thorsten Schneider
Publikováno v:
Biomedical Engineering / Biomedizinische Technik. 62
Publikováno v:
Physics in Medicine and Biology. 60:175-193
The response of the alanine dosimeter to radiation from an Ir-192 source with respect to the absorbed dose to water, relative to Co-60 radiation, was determined experimentally as well as by Monte Carlo simulations. The experimental and Monte Carlo re
Publikováno v:
Physics in Medicine and Biology. 57:6245-6268
For medium energy x-rays produced with tube voltages from 70 to 280 kV, the absorbed dose to water, D(w), has been determined by means of water calorimetry with relative standard uncertainties ranging from 0.45% to 0.98% at 280 and 70 kV. The results
Autor:
Markus Bambynek, T. Sander, Jacco de Pooter, F. Gabris, M P Toni, A.S. Guerra, I. Aubineau-Lanièce, Thorsten Schneider, H. J. Selbach
Publikováno v:
Metrologia. 49:S219-S222
In 2008, the European project ‘T2.J06, Increasing cancer treatment efficacy using 3D brachytherapy’ was launched. One of the main goals of the Joint Research Project was the experimental determination of the dose rate constant Λ to allow the lin
Autor:
H. J. Selbach, Thorsten Schneider
Publikováno v:
Radiotherapy and Oncology. 100:442-445
A large air-filled parallel-plate extrapolation chamber in a phantom of water-equivalent material is used as a primary standard measuring device for low-energy interstitial brachytherapy sources from which the unit of absorbed dose to water can be de
Publikováno v:
Metrologia. 45:422-428
A large air-filled parallel-plate extrapolation chamber with thin graphite front and back electrodes is used as a primary standard measuring device for low-energy interstitial brachytherapy sources from which the unit of air-kerma strength or referen
Publikováno v:
Metrologia. 44:407-414
An accurate determination of the dose produced by brachytherapy seeds emitting low-energy photons is an important component of the radiotherapeutic process. As yet, the output of these seeds has usually been specified in terms of the air kerma rate.
Publikováno v:
Medical physics. 42(7)
Purpose: The aim of this study was to investigate whether a chamber-type-specific radiation quality correction factor kQ can be determined in order to measure the reference air kerma rate of 60Co high-dose-rate (HDR) brachytherapy sources with accept
Publikováno v:
Radiation and Environmental Biophysics. 45:93-98
The production of dicentric chromosomes in human lymphocytes by beta-particles of yttrium-90 (Y-90) was studied in vitro to provide a basis of biological dosimetry after radiosynoviorthesis (RSO) of persistent synovitis by intra-articular administrat
Publikováno v:
Metrologia. 49:S246-S248
A secondary standard of the BEV, calibrated at the PTB in terms of Dw,1 cm, was used for calibration of the well-type chamber-based measuring systems used in clinics. In addition to the calibration, we tried to employ it for assessment of treatment p