Zobrazeno 1 - 10
of 42
pro vyhledávání: '"H. Gaiser"'
Publikováno v:
Environmental Research Letter
Much of Africa is among the world’s regions with lowest yields in staple food crops and climate change is expected to make it more difficult to catch up in crop production in particular in the long run. Various agronomic measures have been proposed
Publikováno v:
IEEE Transactions on Magnetics. 32:2651-2654
The magnets and power supplies of a raster scanning system for a particle therapy facility have been designed and carefully measured after delivery. Well known and proven techniques have been used in construction and production of the laminated windo
Publikováno v:
IEEE Transactions on Magnetics. 30:2650-2653
A versatile Magnet Measuring Device is described, that produces large maps of the three field components in a volume of 2.7 m/spl times/1 m/spl times/1 m. Its main components are: the machine itself, which is based on a large granite table with slide
Publikováno v:
IEEE Transactions on Magnetics. 30:2507-2510
The fragment separator is a device for producing and separating exotic nuclear beams. The exotic nuclei can be investigated directly, or the secondary beams can be injected into the storage-cooler ring, or delivered to targets in the experimental cav
Publikováno v:
Zeitschrift für Palliativmedizin. 7
Publikováno v:
Proceedings of the 1999 Particle Accelerator Conference (Cat. No.99CH36366).
The new 1.4 MeV/u prestripper linac at GSI will provide intense ion beams to fill the synchrotron SIS to the space charge limit for all elements up to uranium. The design mass to charge ratio A/q is 65, the effective acceleration voltage of the 30 m
Publikováno v:
Anasthesiologie, Intensivmedizin, Notfallmedizin, Schmerztherapie : AINS. 32(5)
In a 32 years old patient with advanced gastric cancer epidural analgesia with local anaesthetic and morphine via a thoracic epidural catheter was required because of intractable pain and intolerable side effects of intravenous morphine. In spite of
Publikováno v:
Fertility and Sterility. 84:S9-S10
Autor:
Yu.N. Pestov, E. Badura, Hr Schmidt, H. Gaiser, P Steinhaeuser, J. Eschke, Ch Neyer, M.A. Tiunov, V Lobanov, V. Dodokhov, V Grigoriev, H.H. Gutbrod, R. Schulze, A.R. Frolov, U. Kopf, S Vodopianov, V Kaplin, H. Stelzer
The performance of a new ALICE prototype of the Pestov spark counter was measured both in a dedicated test beam as well as in a high multiplicity heavy-ion environment. Results in terms of time resolution and background behaviour are presented.
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::261bbf617c1a516fcfdb403579c00084
http://cds.cern.ch/record/305520
http://cds.cern.ch/record/305520
Autor:
P Steinhaeuser, C. Neyer, E. Badura, U. Kopf, V. Dodokhov, R. Schulze, H. Gaiser, B. Roters, H.H. Gutbrod, H. Stelzer, Hr Schmidt, A.R. Frolov, Yu.N. Pestov, J. Eschke, M.A. Tiunov
A prototype Pestov Spark Counter with two-dimensional position resolution has been developed. The position resolution is 0.32 mm and
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::bbef2488f5bd3480a9e7a41540208ad0
http://cds.cern.ch/record/295184
http://cds.cern.ch/record/295184