Zobrazeno 1 - 10
of 10
pro vyhledávání: '"H. G. Ostrow"'
Publikováno v:
The Second Annual Symposium on Computer Application in Medical Care, 1.
The advent of nuclear cardiology has resulted in computers playing an increasingly prominent role in nuclear medicine. Frequently, the requirements of nuclear cardiology - especially first pass and gated equilibrium studies - set the hardware and sof
Autor:
M V, Green, W R, Brody, M A, Douglas, J S, Borer, H G, Ostrow, B R, Line, S L, Bacharach, G S, Johnston
Publikováno v:
Journal of nuclear medicine : official publication, Society of Nuclear Medicine. 19(8)
Left-ventricular (LV) ejection fraction (EF) was determined from ECG-gated images of the cardiac blood pool, by computing the relative change in net LV counts occurring in these images during systole. EFs obtained with this method gave satisfactory i
Publikováno v:
Nuklearmedizin. Nuclear medicine. 20(3)
Publikováno v:
Journal of nuclear medicine : official publication, Society of Nuclear Medicine. 16(1)
The cardiac blood pool is visualized with high temporal resolution during a complete, average, cardiac cycle. The technique yields both qualitative and quantitative measures of cardiac performance.
Publikováno v:
Journal of nuclear medicine : official publication, Society of Nuclear Medicine. 18(1)
A minicomputer-based system is described that allows real-time construction and simultaneous display, in flicker-free movie format, of a cardiac-cycle-spanning sequence of ECG-gated scintigraphic images. In as little as 2 min, the endless-loop flicke
Publikováno v:
Journal of nuclear medicine : official publication, Society of Nuclear Medicine. 21(4)
Ejection fraction, normalized peak ejection and filling rates, and the time of occurrence of these events relative to the R-wave were determined in each of 512 consecutive individual cardiac cycles in each of 30 patients using an ultra-high-efficienc
Publikováno v:
Journal of nuclear medicine : official publication, Society of Nuclear Medicine. 18(12)
A nonimaging, ECG-gated scintillation-probe system is described that permits real-time quantification, at high temporal resolution, of the time variation of left ventricular (LV) volume over a complete, average cardiac cycle. Linearity between counti
Publikováno v:
Journal of nuclear medicine : official publication, Society of Nuclear Medicine. 22(3)
The assumptions necessary to perform ECG-gated cardiac studies are seemingly not valid for patients in atrial fibrillation (AF). To evaluate the effect of AF on equilibrium gated scintigraphy, beat-by-beat measurements of left-ventricular function we
Autor:
Lawrence J. Lesko, Harold G. Ostrow, Sandro Betocchi, Rita M. Watson, Douglas R. Rosing, Richard O. Cannon, Robert O. Bonow
Publikováno v:
The American journal of cardiology. 61(10)
The relation between nifedipine concentration and hemodynamic effects after sublingual administration of 10 or 20 mg was examined in 13 patients with nonobstructive hypertrophic cardiomyopathy (HC). Serum nifedipine concentrations were determined by
Autor:
Sandro Betocchi, Cannon Iii, R. O., Watson, R. M., Bonow, R. O., Ostrow, H. G., Epstein, S. E., Rosing, D. R.
Publikováno v:
Scopus-Elsevier
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=dedup_wf_001::415000c97dffccb5c38235def5c900ac
http://www.scopus.com/inward/record.url?eid=2-s2.0-0022381316&partnerID=MN8TOARS
http://www.scopus.com/inward/record.url?eid=2-s2.0-0022381316&partnerID=MN8TOARS