Zobrazeno 1 - 10
of 27
pro vyhledávání: '"H. Buchröder"'
Publikováno v:
Radiation Protection Dosimetry. 167:298-301
The Bundesamt für Strahlenschutz (Berlin, Germany) and the Paul Scherrer Institute (Villigen, Switzerland) both operate accredited calibration laboratories for radon gas activity concentration. Both the institutions use Lucas Cells as detector in th
Publikováno v:
Applied Radiation and Isotopes. 67:876-880
Performance tests of electronic instruments measuring the activity concentration of 222 Rn have been carried out with respect to the standard IEC 61577-2. In total, 9 types of instrument operating with ionization chambers or electrostatic collection
Publikováno v:
Radiation Protection Dosimetry. 125:572-575
Since 2003, the German Federal Office for Radiation Protection (BfS) has conducted annual interlaboratory comparisons for passive radon measuring devices in order to ensure the quality of these measurements. Passive radon devices which use solid stat
Autor:
G. Butterweck, R. Dersch, W. Herzog, A. Rox, V. Schmidt, A. Paul, P. Hamel, Ch. Schuler, H. Buchröder, A. Honig
Publikováno v:
Radiation Protection Dosimetry. 98:219-222
The traceability chain of one national reference laboratory (PTB) and three accredited radon calibration laboratories (BfS MPA and PSI) to internationally acknowledged radon gas standards is specified. As an additional tool for quality assurance, int
Autor:
P. Goloshapov, I. Winkelmann, C. Brummer, S. Mundigl, G. N. Romanov, H. Buchröder, M. Thomas, P. Gesewsky, W. Burkart
Publikováno v:
Radiation and Environmental Biophysics. 37:57-61
A region between Chelyabinsk and Ekaterinburg in the Southern Urals has been heavily contaminated due to operational and accidental releases from the first Soviet plutonium production facility Mayak. In 1992 and 1993, the German Federal Office for Ra
Publikováno v:
Radiation protection dosimetry. 158(1)
This paper analyses the data having been gathered from interlaboratory comparisons of passive radon instruments over 10 y with respect to the measurement accuracy. The measurement accuracy is discussed in terms of the systematic and the random measur
Publikováno v:
Radiation Protection Dosimetry. 34:353-356
Thermoluminescence detectors have been used in national radiation surveillance programmes in the GDR for more than 15 years. The detectors and dosemeters used for individual monitoring (whole body or hand exposures), for selected workplace studies, f
Autor:
Arturo Vargas, Edel-maier R, V. Schmidt, I. Burian, N. Michielsen, G. Butterweck, P. Jachs, Christopher Howarth, N. Hagberg, Annette Röttger, Ch. Schuler, Tuukka Turtiainen, A. Honig, H. Buchröder, X. Ortega, A. Rox, F.J. Maringer, J.C.H. Miles
Publikováno v:
Applied Radiation and Isotopes
Applied Radiation and Isotopes, 2006, 64 (10-11), pp.1102-1107. ⟨10.1016/j.apradiso.2006.02.086⟩
Applied Radiation and Isotopes, 2006, 64 (10-11), pp.1102-1107. ⟨10.1016/j.apradiso.2006.02.086⟩
For the first time, a comparison of radon activity concentration in air has been performed within the scope of Euromet. In the project 657, 'Comparison of calibration facilities for the radon activity concentration,' 12 participants from 9 countries
Autor:
F.J. Maringer, N. Michielsen, Arturo Vargas, A Honig, Annette Röttger, H. Buchröder, J.C.H. Miles, V. Voisin, A. Rox, G. Butterweck, Ch. Schuler, I. Burian, V. Schmidt
Publikováno v:
Radioactivity in the Environment ISBN: 9780080441375
Publisher Summary International intercalibration and intercomparison exercises are used as an important tool to provide confidence in the capability of national metrology institutes and calibration laboratories. The quality systems of national instit
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::3b9f58c464f40c799b3dddafd3ebc1ce
https://doi.org/10.1016/s1569-4860(04)07034-2
https://doi.org/10.1016/s1569-4860(04)07034-2
Autor:
Tuukka Turtiainen, Ch. Schuler, G. Butterweck, I. Burian, J.C.H. Miles, H. Buchröder, Arturo Vargas, A. Rox, F.J. Maringer, Edel-maier R, N. Michielsen, A Honig, Nils Hagberg, P. Jachs, Christopher Howarth, Annette Röttger, V. Schmidt, X. Ortega
Publikováno v:
Metrologia
Metrologia, 2005, 42 (SUPPL.), pp.06003. ⟨10.1088/0026-1394/42/1A/06003⟩
Metrologia, 2005, 42 (SUPPL.), pp.06003. ⟨10.1088/0026-1394/42/1A/06003⟩
Prior to 2002, no comparisons of radon activity concentration had been performed within the scope of the EUROMET. The comparison presented here fulfils the need to provide confidence in the capability of national metrology institutes and calibration
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::963a6cb6bbd61a1e6402d61a9e352122
https://hal.archives-ouvertes.fr/hal-03031162
https://hal.archives-ouvertes.fr/hal-03031162