Zobrazeno 1 - 10
of 196
pro vyhledávání: '"H. Baadenhuijsen"'
Publikováno v:
Clinical Chemistry. 55:549-558
Background: The literature regarding the nonspecificity of applications of the Jaffe (alkaline picrate) reaction for creatinine is generally outdated. We conducted a specificity study to update the nonspecificity information for current Jaffe and enz
Autor:
Marjolein Visser, Lex M. Bouter, Bianca W. M. Schalk, Brenda W.J.H. Penninx, H. Baadenhuijsen, Dorly J. H. Deeg
Publikováno v:
Aging-Clinical and Experimental Research, 17(4), 297-305. Springer Verlag
Aging Clinical and Experimental Research, 17(4), 297-305. Springer Verlag
Schalk, B W M, Visser, M, Penninx, B W J H, Baadenhuijsen, H, Bouter, L M & Deeg, D J H 2005, ' Change in serum albumin and subsequent decline in functional status in older persons. ', Aging-Clinical and Experimental Research, vol. 17, no. 4, pp. 297-305 . https://doi.org/10.1007/BF03324614
Schalk, B W M, Visser, M, Penninx, B W J H, Baadenhuijsen, H, Bouter, L M & Deeg, D J H 2005, ' Change in serum albumin and subsequent decline in functional status in older persons ', Aging Clinical and Experimental Research, vol. 17, no. 4, pp. 297-305 . https://doi.org/10.1007/BF03324614
Aging Clinical and Experimental Research, 17(4), 297-305. Springer Verlag
Schalk, B W M, Visser, M, Penninx, B W J H, Baadenhuijsen, H, Bouter, L M & Deeg, D J H 2005, ' Change in serum albumin and subsequent decline in functional status in older persons. ', Aging-Clinical and Experimental Research, vol. 17, no. 4, pp. 297-305 . https://doi.org/10.1007/BF03324614
Schalk, B W M, Visser, M, Penninx, B W J H, Baadenhuijsen, H, Bouter, L M & Deeg, D J H 2005, ' Change in serum albumin and subsequent decline in functional status in older persons ', Aging Clinical and Experimental Research, vol. 17, no. 4, pp. 297-305 . https://doi.org/10.1007/BF03324614
BACKGROUND AND AIMS: This study examines whether a three-year change in serum albumin concentration is associated with subsequent decline in functional status in older persons. METHODS: A total of 588 participants from the Longitudinal Aging Study Am
Publikováno v:
Annals of Clinical Biochemistry, 37, pp. 330-337
Annals of Clinical Biochemistry, 37, 330-337
Annals of Clinical Biochemistry, 37, 330-337
Clinical chemistry laboratory results from different laboratories often show large between-laboratory variation due to factors such as differences in method principles, method applications, calibration procedures or the application of different instr
Autor:
Louwerens Zwang, Pierre N.M. Demacker, H. Baadenhuijsen, Cas Weykamp, Christa M. Cobbaert, Paul G.H. Mulder
Publikováno v:
Clinical Chemistry. 45:360-370
Background: Standardization of HDL-cholesterol is needed for risk assessment. We assessed for the first time the accuracy of HDL-cholesterol testing in The Netherlands and evaluated 11 candidate reference materials (CRMs). Methods: The total error (T
Autor:
H. Baadenhuijsen, Cas Weykamp, G. J. M. Boerma, Pierre N.M. Demacker, M. Hessels, Hans L. Willems, T. J. Penders
Publikováno v:
Clinical Chemistry. 41:724-730
We studied the suitability of various types of human serum preparations to test the accuracy of total cholesterol measurements in the External Quality Assessment scheme in The Netherlands, in which approximately 180 laboratories participate. Checked
Autor:
H. Baadenhuijsen, W. Martina, T. J. Penders, F. A. J. Muskiet, Cas Weykamp, F.W.P. van der Slik
Publikováno v:
Clinical Chemistry, 41, 713-716
Clinical Chemistry, 41, pp. 713-716
Clinical Chemistry, 41, 5, pp. 713-716
Clinical Chemistry, 41, pp. 713-716
Clinical Chemistry, 41, 5, pp. 713-716
Three groups of 10 age- and sex-matched nondiabetic volunteers took 0, 750, or 1500 mg of vitamin C each day for 12 weeks. Glycohemoglobin (GHb) was measured by HPLC, electrophoresis, affinity chromatography, and immunoassay at baseline (-4 weeks and
Publikováno v:
Clinical Chemistry. 37:1196-1204
The Dutch Foundation for Quality Assessment in Clinical Chemistry (SKZL) is the professional organization that conducts external quality-assessment schemes in The Netherlands. However, such schemes in fact assess the performance of the internal quali
Publikováno v:
Clinical Chemistry and Laboratory Medicine, 43, 304-7
Clinical Chemistry and Laboratory Medicine, 43, 3, pp. 304-7
Clinical Chemistry and Laboratory Medicine, 43, 3, pp. 304-7
The performance of suitable secondary reference material for the use of trueness control of six routinely measured clinical enzymes in the Dutch External Quality Assessment (EQA) scheme is described. The reference material of choice was selected usin
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::1436f9a7c2b399bdf8e8bfe95d06d3b3
http://hdl.handle.net/2066/32500
http://hdl.handle.net/2066/32500
Autor:
Christa M. Cobbaert, Rob Jansen, H. Baadenhuijsen, Cas Weykamp, Aldy Kuypers, Herman Steigstra
Publikováno v:
Clinical Chemistry, 48, 1520-5
Scopus-Elsevier
Clinical Chemistry, 48, 9, pp. 1520-5
Europe PubMed Central
Scopus-Elsevier
Clinical Chemistry, 48, 9, pp. 1520-5
Europe PubMed Central
Background: The Dutch project “Calibration 2000” aims at harmonization of laboratory results via calibration by development of commutable, matrix-based, secondary reference materials. An alternative approach to the NCCLS EP14 protocol for studyin
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::af418f41f525158423e0b6ea43d09a1a
http://hdl.handle.net/2066/186515
http://hdl.handle.net/2066/186515
Publikováno v:
Nederlands tijdschrift voor geneeskunde. 143(13)
The anion gap is used to evaluate disturbances in the acid-base balance, in particular metabolic acidosis. Due to the introduction of new clinical chemical techniques and modern analysers the reference range of the anion gap has changed. Clinical che