Zobrazeno 1 - 10
of 14
pro vyhledávání: '"H Jay, Wisnicki"'
Publikováno v:
American Journal of Ophthalmology. 137:944-946
PURPOSE: To evaluate anterior segment retinoblastoma with high-frequency ultrasound. DESIGN: Interventional case report. METHODS: An 11-year-old boy with a total retinal detachment and multiple white anterior chamber nodules was examined with high-fr
Autor:
Michael J. Newton, Joel S. Mindel, Donna J. Gagliuso, Robin N. Ginsburg, H. Jay Wisnicki, Penny A. Asbell, Scott E. Brodie
Publikováno v:
Survey of Ophthalmology. 39:74-83
Publikováno v:
Ophthalmology. 97:1259-1264
The apparent optical axis of an implanted intraocular lens (IOL) can be located by alignment of the examiner's hand light with the third and fourth Purkinje images from the front and back surfaces of the IOL. Tilt of the IOL can be estimated (or meas
Publikováno v:
Ophthalmology. 113(6)
To present giant conjunctival inclusion cysts as a late complication of strabismus surgery.Retrospective case series of selected patients.Four patients with a history of strabismus surgery who had developed giant conjunctival inclusion cysts.A chart
Publikováno v:
Clinical cardiology. 19(3)
Retinal artery embolization is an unusual but serious complication of calcific aortic stenosis. However, it is rare for retinal embolization to be the presenting feature of aortic stenosis. This report describes a young patient who presented with an
Publikováno v:
Ophthalmology. 113:1045-1049.e2
Purpose To present giant conjunctival inclusion cysts as a late complication of strabismus surgery. Design Retrospective case series of selected patients. Participants Four patients with a history of strabismus surgery who had developed giant conjunc
Autor:
H. Jay Wisnicki
Publikováno v:
American Journal of Ophthalmology. 119:116
Autor:
Hugh R. Taylor, James P. Buchman, Michael X. Repka, Marcia J. Riley, David L. Guyton, Kevin M. Miller, H. Jay Wisnicki
Publikováno v:
Ophthalmology. 95:403-409
The Wilmer Information System is a computerized medical information system used for the storage and retrieval of data pertaining to patient demographics, diagnosis, and therapy. The heart of the system is an expandable, hierarchical code based on Int
Publikováno v:
Journal of Refractive Surgery. 3:50-52
A modified corneal press was developed to allow a donor corneal scleral button to be compressed to normal dimensions, or other than normal thickness If desired, The compressed cornea has a normal variation in thickness from center to periphery. Modif
Publikováno v:
Archives of otolaryngology--headneck surgery. 114(10)
• With the advent of extremely rapid, powerful, compact, and inexpensive microcomputers, a revolution in data manipulation is ongoing. We have customized and used for over two years prepackaged software to track residents' operative experiences in