Publikováno v:
American journal of clinical pathology. 114(5)
We studied the relation between ionized magnesium, total magnesium, and albumin levels in serum of 115 critically ill patients and the role of extracellular and intracellular magnesium in outcome prediction. Levels of serum total and ionized magnesiu
Publikováno v:
European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies. 35(8)
The aim of this article is to describe guidelines for rational use of lactate dehydrogenase and its isoenzymes, in the diagnostic processes and during follow-up, based on a systematic review of relevant literature. Sources of data for this study were
Publikováno v:
Peritoneal dialysis international : journal of the International Society for Peritoneal Dialysis. 16(5)
To evaluate the use of low-calcium solution as the standard solution in chronic peritoneal dialysis patients.Prospective long-term follow-up study over a one-year period.University hospital.The change of the calcium concentration of the dialysate fro
Publikováno v:
Clinical chemistry. 40(1)