Metrologia. 55:06009
A supplementary comparison has been made between the air-kerma standards of the NRPA (Norway), the STUK (Finland) the SSM (Sweden) and the LNE-LNHB (France) in the ISO 4037 narrow spectrum series in the range 40 kV to 300 kV. The technical protocol w
Publikováno v:
Metrologia. 55:06007
A supplementary comparison has been made between the air-kerma standards of the NRPA, Norway, the STUK, Finland, the SSM, Sweden and the LNE-LNHB, France in the medium-energy x-ray range. The technical protocol was approved by the CCRI(I) in April 20
Publikováno v:
Metrologia. 55:06008
A supplementary comparison has been made between the air-kerma standards of the NRPA, Norway, the STUK, Finland, the SSM, Sweden and the LNE-LNHB, France in the low-energy x-ray range, and between the NRPA and the LNE-LNHB in the mammography x-ray ra
Publikováno v:
Acta Oncologica. 48:289-294
In the summer of 2007 the secondary standard dosimetry laboratory (SSDL) in Norway established a calibration service for reference air-kerma product meter (KAP-meter). The air-kerma area product, P(KA), is a dosimetric quantity that can be directly r
Publikováno v:
Radiation Measurements. 39:21-28
The dose-to-water response of the EPR alanine dosimetry system for various electron beams used in radiotherapy is studied. The EPR alanine dosimetry system is established for high-dose dosimetry, usually transfer dosimetry of 60 Co γ-rays. However,
Autor:
Christopher G. Blood, Juan Carlos Puyana, H. Bjerke, James M. Zouris, David B. Hoyt, Julia Fridman, Paul J. Pitlyk, G. J. Walker, J. Zhang
Publikováno v:
The Journal of Trauma: Injury, Infection, and Critical Care. 53:1160-1165
We examined clinical records of combat casualties that died subsequent to reaching a medical treatment facility in an effort to determine whether new medical technologies or enhanced training might contribute to a reduction in combat deaths.Hospital
Autor:
T Genka, Frans Verhaegen, D Santry, M.J. Rossiter, M.J. Woods, G. Sibbens, T.T. Williams, Jan Seuntjens, Hubert Thierens, J.P. Sephton, N Drugge, H Bjerke, D.F.G. Reher, A.H.L Aalbers
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 339:386-390
At the occasion of the EUROMET Workshop on Ionising Radiation and Radioactivity at the NPL, it was decided to carry out a second intercomparison on air kerma rate (AKR) and activity measurements on 192 Ir brachytherapy sources in the frame of EUROMET
Autor:
P. Toroi, A. Megzifene, V. Sochor, J. Cardoso, H. Jarvinen, L. C. Mihailescu, A Kosunen, M. Ginjaume, Istvan Csete, J. E. Grindborg, L Büermann, L. Novak, M. Brodecki, L Persson, C. J. Hourdakis, P. Ferrari, J. Compel, J. Daures, Olivera Ciraj-Bjelac, S. Bercea, H. Bjerke, J. dePooter, G. Einarsson, M. Pedersen, M Denoziere, D. Glavič-Cindro
Publikováno v:
Metrologia. 52:06024
The EURAMET #1177 project, identified as EURAMET RI(I) - S9 comparison, was the first EURAMET wide scale supplementary comparison in the field of diagnostic radiology for air kerma area product, PKA, and air kerma, K. It was conducted with the goal o
Autor:
F Pernicka, J.-E. Grindborg, I Csete, Antti Kosunen, François Bochud, J Witzani, W. de Vries, H M Kramer, C. J. Hourdakis, T Sander, M Denoziere, H Bjerke, K. Ennow
Publikováno v:
Radiation Protection Dosimetry, vol. 108, no. 1, pp. 33-45
The effect of different X ray radiation qualities on the calibration of mammographic dosemeters was investigated within the framework of a EUROMET (European Collaboration in Measurement Standards) project. The calibration coefficients for two ionizat
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::7d88b74eccf9031beeb6e4bb2c8ef2f4
https://serval.unil.ch/resource/serval:BIB_F7BA4D0F02FD.P001/REF.pdf
https://serval.unil.ch/resource/serval:BIB_F7BA4D0F02FD.P001/REF.pdf