Zobrazeno 1 - 10
of 12
pro vyhledávání: '"H B, Barber"'
Publikováno v:
Lecture Notes in Computer Science ISBN: 3540542469
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::3907a1ef0cc217cf9070d11c32679a01
https://doi.org/10.1007/bfb0033738
https://doi.org/10.1007/bfb0033738
Publikováno v:
SPIE Proceedings.
The coincidence timing resolution is a critical performance parameter to determine if direct gamma-ray detection by semiconductor detector material such as CdTe or CdZnTe may be suitable for use in positron emission tomography systems. We report expe
Publikováno v:
Medical physics. 18(3)
Spatial variation in the background source distribution makes tumor detection difficult for single-detector probes. Using a single energy window that brackets the photopeak helps discriminate against background events dominated by Compton scattering.
Autor:
H B, Barber, H H, Barrett, T S, Hickernell, D P, Kwo, J M, Woolfenden, G, Entine, C, Ortale Baccash
Publikováno v:
Medical physics. 18(3)
The physical properties of three surgical probes containing different radiation detectors are compared: a NaI(Tl) scintillator with a flexible, fiber-optic light guide, and two semiconductor detectors that operate at room temperature, CdTe and HgI2.
Publikováno v:
Physical Review Letters. 48:856-859
Cosmic-ray nuclei have been observed to produce 2072 secondary fragments in nuclear interactions detected in nuclear emulsions. These fragments produce 557 further interactions. Previous reports that these secondary nuclei show anomalously short mean
Publikováno v:
Journal of nuclear medicine : official publication, Society of Nuclear Medicine. 29(6)
A hand-held, dual-detector probe has been developed for surgical tumor staging. This dual probe simultaneously monitors counts from a possible tumor site along with counts from adjacent normal tissue using two concentric, collimated scintillation det
Publikováno v:
Medical physics. 15(2)
We used an observer-performance study to compare four different modes of presenting count-rate data from a radiation detector. Observers searched for small, concealed radioactive sources using a hand-held radiation-detector probe. The modes of count-
Autor:
James M. Woolfenden, Walter J. Wild, Harrison H. Barrett, K. J. Myers, W. E. Smith, P. A. Ervin, R. G. Paxman, H. B. Barber
Publikováno v:
Information Processing in Medical Imaging ISBN: 9789400960473
It has now been over a decade since the idea of coded apertures as an alternative to conventional pinholes and collimators was first proposed in the nuclear medicine literature. During this period, many different codes and decoding algorithms have be
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::dfbed922513a5b16588808ef7accecf1
https://doi.org/10.1007/978-94-009-6045-9_7
https://doi.org/10.1007/978-94-009-6045-9_7
Publikováno v:
Medical physics. 11(4)
We adapted a small sodium iodide scintillation detector for rapid, in vivo localization of a lost brachytherapy seed. Using the detector, we were able to locate and remove an Ir-192 seed that was not visible to the unaided eye.
Autor:
Jay B. Holberg, H. B. Barber
Publikováno v:
The Astrophysical Journal. 292:16
A series of high-galactic-latitude observations made with the Voyager 2 ultraviolet spectrometer are used to place stringent upper limits on the far-ultraviolet emissions from the central regions of the Coma Cluster of galaxies. In particular, consid